Simulation and Analysis of Energy Consumption of Public Building in Chongquig
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Calculation and analysis of energy consumption must be on the base of simulation of
building load. DeST is adopted to calculate dynamic cooling load of the main building in Chongqing city.
Then water chilling unit's plant ...
Analysis of the Double Window in Saving Energy and Economical Efficiency in Nanjing in the Winter
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
With the rapid progress of the economy, heating in winter is widespread in the eastern area of China. According to the exterior-protected structure of buildings in Nanjing, the hourly and dynamic load of energy consumption ...
Analysis of the Effects of the Application of Solar Water Heater in Building Energy Consumption
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
With the development of the economy, civilian construction in the Changjiang River delta region is rapidly expanding. The boom in the construction industry definitely results in that the proportion of building energy ...
The Influence of Operating Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
A field investigation was carried out in an office building of Changsha city in winter and summer, the influence of different running modes, curtain styles and room temperature set point on energy consumption of room air ...
Analysis of a Dedicated Outdoor Air System and Low Temperature Supply Air Conditioning System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
This paper presents the principles and the characteristics of a dedicated outdoor air system (DOAS) and low temperature supply air system. DOAS is offered based on the demands of indoor air quality and the low temperature ...
Investigation and Analysis of Energy Consumption and Cost of Electric Air Conditioning Systems in Civil Buildings in Changsha
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
We investigated 40 typical air conditioned buildings in Changsha in 2005, including 15 hotel buildings, 6 commercial buildings, 5 office buildings, 6 hospital buildings and 8 synthesis buildings. On this basis we analyze ...
An Operational Energy Consumption Evaluation Index System for Large Public Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Large public buildings have been the emphasis of energy conservation in China. In this paper, the design and operational energy consumption evaluation indices for large public buildings are generalized, their differences ...