Monitoring and Verification Procedures Used in the Texas LoanSTAR and Rebuild America Programs
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
The monitoring and verification procedures that
have been developed for the Texas LoanSTAR
program and the ESL's Rebuild America Program
have become a foundation for a number of other state
and federal M&V programs, including ...
Accounting for the Occupancy Variable in Inverse Building Energy Baselining Models
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
The occupancy factor is often
underestimated in inverse modeling of building
energy use, or accounted for by grouping the
daily data in occupied and unoccupied groups
which are modeled separately. For instance, in
institutional ...
Retrofit Savings Determination for Wichita Falls Independent School District
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
ASHRAE's Proposed Guideline 14P for Measurement of Energy and Demand Savings: How to Determine What Was Really Saved by the Retrofit
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
ASHRAE has recently completed the development of
Guideline 14 to fill a need for a standard set of
energy (and demand) savings calculation procedures.
Guideline 14 is intended to be a guideline that
provides a minimum ...
Measured Energy Use Indices for 27 Office Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
Energy use indices for 27 government office buildings are presented that have been assembled from hourly
monitored data as part of the Texas LoanSTAR program and other efforts at the Energy Systems Laboratory. These
indices ...
Development of Load Forecasting Procedures for the Texas A&M University System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
This paper reports on the effort to develop load-forecasting procedures for the Texas A&M University System
(TAMUS). Such procedures are being investigated to determine if the TAMUS can benefit from the pending
deregulation ...
Retrofit Savings for Brazos County
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This report presents the energy and dollar savings for the period May 2000 - April 2001 for 10 of the Brazos County facilities that have been retrofit. The electricity use saved was 555,170 kWh and the demand was 1062 kW, ...
Energy Savings Report For Dallas County, July 2000 – June 2001
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This report presents the energy and dollar savings for the period July 2000 - June 2001 for 12 Dallas County facilities that have been retrofit by Enershop. The savings for this period total $745,046, which represent 73.2% ...
Compilation of Diversity Factors and Schedules for Energy and Cooling Load Calculations, ASHRAE Research Project 1093-RP, Final Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This is the final report for the ASHRAE 1093-RP project. This report presents the method used to derive the diversity factors and typical load shapes of lighting and receptacle loads in office buildings. In this report the ...
Development of a Toolkit for Calculating Linear, Change–Point Linear and Multiple–Linear Inverse Building Energy Analysis Models, ASHRAE Research Project 1050-RP, Detailed Test Results
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This is the detailed test report for the ASHRAE 1050-RP project. This report presents the detailed results of the testing of IMT (Inverse Modeling Toolkit). Two kinds of testing were performed, bounds testing and accuracy ...