Vibration Field Problem Resolved With Analytical Diagnostic Approach And Innovative Impeller Design
(Texas A&M University. Turbomachinery Laboratories, 2007)
Several pump units of the same design installed in various locations is the USA with different duties exhibited high vibrations above API limits with process fluids (SG - 0.5 to 0.6) from rated point down to minimum ...
Pump Cavitation - Various NPSHR Criteria, NPSHA Margins, Impeller Life Expectancy (Unpublished)
(Texas A&M University. Turbomachinery Laboratories, 2007)