Continuous Commissioning Results Verification and Follow-up For an Institutional Building: A Case Study
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
The Kleberg Building on the Texas A&M
University campus is a teaching/research facility
consisting of classrooms, offices and laboratories,
with a total floor area of approximately 165,030 ft2.
Continuous Commissioning ...
The Temperature and Relative Humidity Control in Cushing Library
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Cushing Library located on TAMU campus is a
special building, which needs precise temperature
and relative humidity control, because it stores a
number of rare collections and memorial books.
There are five air-handling ...
Eliminating Humidity and Condensation Problems in University Dormitories - Case Study
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2002)
Krueger Hall, McFadden Hall and Rudder Hall are
dormitories used for housing on-campus students of
Texas A&M University (TAMU). These halls have
suffered with humidity problems for many years.
The Continuous Commissioning ...
Chilled Water System Hydraulic Study for The University of Texas at San Antonio
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)
The University of Texas at San Antonio needs to expand their central chilled water distribution system as a result of planned additions to the
campus. The current distribution system may be inadequate for the planned ...
The Chilled Water and Hot Water Building Differential Pressure Setpoint Calculation - Chilled Water and Hot Water Pump Speed Control
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
More and more variable frequency devices (VFD)
are being installed on the chilled water and hot water
pumps on the TAMU campus. Those pump speeds
are varied to maintain chilled water or hot water
building deferential ...
Results of CC Follow-Up in the G. Rollie White Building
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
An investigation into the increase of energy
consumption of G. Rollie White Coliseum was part
of the persistence project[1], which investigates the
savings in energy consumption of ten buildings that
were commissioned by ...
Improving Boiler Efficiency Modeling Based On Ambient Air Temperature
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Optimum economic operation in a large
power plant can cut operating costs substantially.
Individual plant equipment should be operated
under conditions that are most favorable for
maximizing its efficiency. It is widely ...
Chiller Start/Stop Optimization for a Campus-wide Chilled Water System with a Thermal Storage Tank Under a Four-Period Electricity Rate Schedule
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
The existence of a 1.4-million-gallon
chilled water thermal storage tank greatly
increases the operational flexibility of a campuswide
chilled water system under a four-part
electricity rate structure. While significant
...
Correcting Thermal Distribution Problems for a Large University Campus
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Texas A&M University main campus in
College Station consists of 114 buildings served by
two central plants. The two main campus loops are
more than 50 years old with a total piping length for
each loop in excess of 13 ...
Rehabilitation of Secondary Heating and Cooling Systems - Case Study
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Continuous Commissioning (CCSM) was performed
on the Texas A&M Large Animal Hospital in
October 1996 and as a result, significant savings were
achieved. Subsequently, the building chilled water
and hot water energy consumption ...