Recommendations for 2009 IECC 15% Above Code Energy Efficiency Measures for Residential Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-11)
In the 79th Legislature (2005) the Energy Systems Laboratory was required to develop three alternative methods for achieving 15% above-code energy savings in new residential, commercial and industrial construction. The ...
A Comparative Analysis of Residential Energy Use for 2009 IECC Code Compliance and 2001 IECC Compliance with 2006 NAECA Appliance Standards for Selected Climate Zones in Texas
(Energy Systems Laboratory (Http://esl.tamu.edu), 2010-08)
This paper presents results of a comparative analysis of the electricity and natural gas savings from the implementation of 2009 International Energy Conservation Code (IECC) when compared with the 2001 IECC1 specifications ...
A Methodology for Calculating Emissions Reductions from Renewable Energy Programs and its Application to the Wind Farms in the Texas ERCOT Region
(Energy Systems Laboratory (http://esl.tamu.edu), 2007-12)
Going Beyond a Resnet Certification for Code-Compliant Simulations: A Sensitivity Analysis of Detailed Results of Three RESNET-Certified, Code-Compliant Residential Simulation Programs
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
In many states building code officials rely on certified, code-compliant simulations to determine whether or not a residence satisfies the energy code requirements using a performance-path analysis. In the United States, ...
Analysis of Emissions Calculators for the National Center of Excellence on Displaced Emission Reductions (CEDER)- 2008 Annual Report to the United States Environmental Protection Agency
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-02)
In August 2004, the USEPA issued guidance on quantifying the air emission benefits from electric sector
energy efficiency and renewable energy. Because there was no clear best strategy, the EPA’s guidance
provided a ...
Energy Efficiency/ Renewable Energy Impact in the Texas Emisions Reduction Plan (TERP): Volume II- Technical Report
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2011)
The Energy Systems Laboratory (Laboratory), at the Texas Engineering Experiment Station of The Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP) Preliminary Report: Integrated NOx Emissions Savings from EE/RE Programs Statewide
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-07)
The Energy Systems Laboratory (Laboratory), at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. § 388.003 (e), ...
Energy Efficiency/ Renewable Energy Impact in the Texas Emisions Reduction Plan (TERP): Volume III- Technical Appendix
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2011)
The Energy Systems Laboratory (Laboratory), at the Texas Engineering Experiment Station of The Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon ...
Energy Efficiency/ Renewable Energy Impact in the Texas Emisions Reduction Plan (TERP): Volume I- Summary Report
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2011)
The Energy Systems Laboratory (Laboratory), at the Texas Engineering Experiment Station of The Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon ...
Calculating Emissions Reductions from Renewable Energy Programs and its Application to the Wind Farms in the Texas Ercot Region
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-12)
In August 2008 the Texas State Legislature required adding 5,880 MW of generating capacity from renewable energy technologies by 2015, and 500 MW from non-wind renewables. This legislation also required the Public Utility ...