Search
Now showing items 1-10 of 17
Validation of the International Code Compliant Calculator (IC3) v3.10 Using the RESNET Verification Procedures
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-12)
This report presents results from the testing and validation of the Energy Systems Laboratory’s web-based software
tool - International Code Compliance Calculator (IC3), v3.10, using the Residential Energy Services ...
Description and Comparison of the Results of the Proposed House: Habitat for Humanity at Frazier Court, Dallas, Texas, with the 2004 IECC Standard Reference House
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-09)
The Energy Systems Laboratory was requested to calculate the emissions reductions associated
with the Habitat for Humanity Housing Project at Frazier Court, Dallas Texas. This report presents the
results of the required ...
Recommendations for 2009 IECC 15% Above Code Energy Efficiency Measures for Residential Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-11)
In the 79th Legislature (2005) the Energy Systems Laboratory was required to develop three alternative methods for achieving 15% above-code energy savings in new residential, commercial and industrial construction. The ...
NOx Emissions Reduction from CPS Energy's "Save For Tomorrow Energy Plan" Within the Alamo Area Council of Governments Report to the Texas Commission on Environmental Quality
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-10)
ESL used the Texas Commission on Environmental Quality’s (TCEQ) Guide for Incorporating Energy Efficiency/Renewable Energy (EE/RE) Projects into the SIP for local entities dated February 6, 2004 to survey potential projects ...
Estimates of Energy Cost Savings Achieved from 2009 IECC Code-Compliant, Single Family Residences in Texas
(Energy Systems Laboratory (http://esl.tamu.edu), 2011-01)
This report presents estimates of the energy cost savings to be achieved from 2009 International Energy
Conservation Code (IECC) code-compliant, single-family residences in Texas compared to the pre-2009
IECC codes, ...
Description and Comparison of the Results of the Proposed House: Habitat for Humanity at Frazier Court, Dallas, Texas, with the 2004 IECC Standard Reference House
(Energy Systems Laboratiry, 2010-09)
The Energy Systems Laboratory was requested to calculate the emissions reductions associated
with the Habitat for Humanity Housing Project at Frazier Court, Dallas Texas. This report presents the
results of the required ...
Analysis of Emissions Calculators for the National Center of Excellence on Displaced Emission Reductions (CEDER)- 2008 Annual Report to the United States Environmental Protection Agency
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-02)
In August 2004, the USEPA issued guidance on quantifying the air emission benefits from electric sector
energy efficiency and renewable energy. Because there was no clear best strategy, the EPA’s guidance
provided a ...
Baseline Report for the Fort Hood Army Base: Sept. 1, 2001 To Aug. 31, 2002
(2002-12)
This report presents electricity, natural gas and cooling baselines for the thermal plant,
buildings located in the 87000 block, and the III Corp building at Ft. Hood. A baseline
analysis is also presented for the natural ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP) Preliminary Report: Integrated NOx Emissions Savings from EE/RE Programs Statewide
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-07)
The Energy Systems Laboratory (Laboratory), at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. § 388.003 (e), ...
Energy Efficiency, Cost-Effectiveness, and Air Pollutant Reduction Analysis From Energy Efficiency and Renewable Energy (EE/RE) Projects in Texas Public Schools
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
The purpose of this report is to provide the preliminary results from an analysis of the potential energy
savings, and resultant air pollution reductions associated with the energy savings from the application of
cost-effective ...