CFD Simulation and Analysis of the Combined Evaporative Cooling and Radiant Ceiling Air-conditioning System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Due to such disadvantages as large air duct and high energy consumption of the current all- outdoor air evaporative cooling systems used in the dry region of Northwest China, as well as the superiority of the ceiling cooling ...
Study of the Influence of Air Supply Temperature on Air Distribution in the Run-through Large Space Architecture
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
The article introduces the concept and features of run-through large space. By using CFD technology, the paper simulates a velocity field and temperature field in the important air conditioned zone of China's science and ...
Numerical Simulation Study on Transpired Solar Air Collector
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
The unglazed transpired solar air collector is now a well-recognized solar air heater for heating outside air directly. In this article, researchers introduced numerical simulation tools into the solar air collector research ...
Analyzing Ventilation Effects of Different Apartment Styles by CFD
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
With more attention being paid to residential apartments, designers have begun to focus their efforts on how to make a design that is not only functional but also practical. This paper gives a summary of a detailed ...
CFD Simulation and Measurement Validation of Air Distribution at the Hunan International Exhibition Center
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
The Hunan International Exhibition Center (HIEC) is a large space building. A stratified air-conditioning system on the second floor of the building has been adopted. Due to some problems with the air supply jet diffuser, ...
Test and Reconstruction of Air Conditioning System in a Hotel Lobby
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Two air conditioning systems are equipped in a hotel lobby. It is found from the field test that the actual air rate is 40% and 16% of the nominal value, respectively, of the two systems, which is far lower than the design ...
Numerical Simulation of a Displacement Ventilation System with Multi-heat Sources and Analysis of Influential Factors
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Displacement ventilation (DV) is a promising ventilation concept due to its high ventilation efficiency. In this paper, the application of the CFD method, the velocity and temperature fields of three-dimensional displacement ...
Numerical Simulation and Experimental Study on Airflow Characteristics in the Plenum of Underfloor Air Supply
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Energy-efficient and cost-effective space conditioning in offices and other commercial buildings usually use the underfloor space for the supply air static-pressure plenum. The airflow in a plenum of the underfloor air ...
A CFD-based Approach for Gas Detectors Allocation
(Mary Kay O'Connor Process Safety Center, 2015)
Accidental gas releases are detected by allocating sensors in optimal places to prevent escalation of the incident. Gas release effects are typically assessed based on calculating the dispersion from releasing points. In ...
Liquefied Natural Gas (LNG) Vapor Dispersion Modeling with Computational Fluid Dynamics Codes
(2012-10-19)
Federal regulation 49 CFR 193 and standard NFPA 59A require the use of validated consequence models to determine the vapor cloud dispersion exclusion zones for accidental liquefied natural gas (LNG) releases. For modeling ...