A Calibration Methodology for Retrofit Projects Using Short-Term Monitoring and Disaggregated Energy Use Data
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
This paper presents an improved methodology to
calibrate energy simulation models to better represent
the actual energy use breakdowns in existing buildings.
The goal of this methodology is to help architects
and engineers ...
Thermal Comfort Study in a Naturally Ventilated Residential Building in a Tropical Hot-Humid Climate Region
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
This paper presents a thermal comfort study in a
naturally ventilated residential building located in a
tropical hot-humid climate region. The specific
objective of this study is to investigate whether
thermal comfort in ...
Effectiveness of External Window Attachments Based on Daylight Utilization and Cooling Load Reduction for Small Office Buildings in Hot Humid Climates
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
This study explored the effectiveness of
selected external shading devices and glazing
treatments used to minimize the total annual energy
consumption in small office buildings in hot humid
climates. The external shading ...
Estimated Savings from Turning Off Unnecessary Electrical Loads During Unoccupied Periods at the Langford Architecture Center
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1996)
This report presents the results of an on-off test conducted to determine the lighting load in the studios on the third and fourth floors of the Langford Architecture Center Building A and the savings that would be achieved ...
Estimated Savings from Turning Off Unnecessary Lights at the Langford Architecture Center During the 1996 Christmas Holidays
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1997)
During the 1996 Christmas holidays the College of Architecture initiated a trial program to turn off unnecessary lights during unoccupied periods. This effort targeted the unnecessary lights in all studios, classrooms, ...
Lighting Survey Results at the Langford Architecture Center and Estimated Savings by Delamping
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1997)
This report presents the results of a survey conducted to measure the illuminance levels in all rooms in the Langford Architecture Center buildings. The purpose of this survey was to investigate which rooms are over ...