Automatic Commissioning of Multiple VAV Terminals
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
A site survey on a modern operating commercial building screened 261 ineffective VAV (Variable
Air Volume) boxes (20.9% of the total boxes in the building) and summarized ten typical faults for VAV
air-conditioning system(s) ...
Analysis of Heating Systems and Scale of Natural Gas-Condensing Water Boilers in Northern Zones
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
In this paper, various heating systems and scale of the natural gas-condensing water boiler in northern zones are discussed, based on a technical-economic analysis of the heating systems of natural gas condensing water ...
A Control Scheme of Enhanced Reliability for Multiple Chiller Plants Using Mergerd Building Cooling Load Measurements
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)
This paper presents a control scheme which utilizes the enhanced instantaneous cooling load measurements to improve the reliability of chiller sequencing control. The enhanced measurement is obtained by merging two different ...
Automatic Continuous Commissioning of Measurement Instruments in Air Handling Units
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
This paper presents a robust strategy based on a condition-based adaptive statistical method for automatic commissioning of measurement instruments typically employed in air-handling units (AHU). The multivariate statistic ...
Discussion on Energy-Efficient Technology for the Reconstruction of Residential Buildings in Cold Areas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
: Based on the existing residential buildings in cold areas, this paper takes the existing residential buildings in a certain district in Beijing to provide an analysis of the thermal characteristics of envelope and energy ...
Health Monitoring and Continuous Commissioning of Centrifugal Chiller Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
This paper presents strategies for detecting and diagnosing the chiller component faults and the sensor
faults involved in chiller conditioning monitoring and control. The two strategies are used in series. One strategy
diagnoses ...
Commissioning and Diagnosis of VAV Air-Conditioning Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
This paper presents a fault detection and diagnosis (FDD) strategy based on system knowledge, qualitative states and object-oriented statistical process control (SPC) models for typical pressure-independent variable air ...
Discussion of an Optimization Scheme for the Ground Source Heat Pump System of HVAC
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
With the implementation of the global sustainable development strategy, people pay more attention to renewable energy resources such as ground source heat pumps. The technology of ground source heat pump is widely applied ...
Economic Analysis and Comparison of Waste Water Resource Heat Pump Heating and Air-Conditioning System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Based on the heating and air-conditioning system of a high-rise residential building in Northern city, this paper provides a discussion on the choice and matching of different types of Waste Water Resource Heat Pump (WWRHP) ...
Hybrid Model for Building Performance Diagnosis and Optimal Control
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2003)
Modern buildings require continuous performance
monitoring, automatic diagnostics and optimal
supervisory control. For these applications, simplified
dynamic building models are needed to predict the
cooling and heating ...