The Use Of Integrally Geared Compressors Based On Two Industrial Gas Companies' Experience.
(Texas A&M University. Turbomachinery Laboratories, 2003)
The industrial gas industry has been using integrally geared compressors for over 35 years. This industry has the most experience in the design aspects, the commissioning, and the operation of this style compressor. With ...
What Are The Differences In High Performance Flexible Couplings For Turbomachinery?
(Texas A&M University. Turbomachinery Laboratories, 2003)
There are many types of couplings used on high performance turbomachinery. Explained are the differences in the various styles and configurations, and when one is preferable to another in certain applications.
Discussion Groups for the Proceedings of the 32nd Turbomachinery Symposium
(Texas A&M University. Turbomachinery Laboratories, 2003)
Instability Of A High Pressure Compressor Equipped With Honeycomb Seals.
(Texas A&M University. Turbomachinery Laboratories, 2003)
A two casing (three-stage) high-pressure injection compressor train driven by a gas turbine via a gearbox was full load and full speed performance tested to demonstrate satisfactory aerothermal and rotordynamic performance. ...
Age Related Failures In Magnetic Bearing Systems.
(Texas A&M University. Turbomachinery Laboratories, 2003)
Magnetic bearings continue to be successfully applied throughout industry. As the population of machines using magnetic bearings grows, so does the interest in the appropriate predictive and preventive maintenance (PPM) ...
Resonance Identification For Impellers.
(Texas A&M University. Turbomachinery Laboratories, 2003)
The reliability of centrifugal compressors for the most part depends on the reliable operation of impellers. Most of the time, damage to impellers is due to mechanical fatigue. Fatigue damage has been observed in blades, ...
Review of Methods for Measuring and Verifying Savings from Energy Conservation Retrofits to Existing Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2003)
The Measurement & Verification (M&V) process has evolved in the last 15 years to provide a high confidence approach for determining the resulting savings from a variety of retrofits and energy efficiency enhancements. M&V ...
U. S. Army Measurement and Verification (M&V) Costing Toolkit
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2003)
This is the 2003 final report for the U.S. Army Monitoring and Verification (M&V) costs project. The purpose of this project is to develop a M&V Costing Toolkit to be used by the government or third party planners to design ...
Overview Of API 682, Second Edition
(Texas A&M University. Turbomachinery Laboratories, 2003)
APIs recent release of Standard 682, Second Edition, represents a major revision to this standard. The latest revision has greatly expanded the scope of the standard by including applications to more pumps, adding new seal ...
Selecting Steam Turbines For Pump Drives
(Texas A&M University. Turbomachinery Laboratories, 2003)
Selecting the right steam turbine for the application can save the purchaser money on initial cost (avoiding oversizing) as well as operating costs (better efficiency). The intent of this paper is to provide steam turbine ...