Search
Now showing items 61-70 of 81
Compilation of Diversity Factors and Schedules for Energy and Cooling Load Calculations, Phase II Report - Identified Relevant Data Sets, Methods, and Variability Analysis
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)
This is the second report of the ASHRAE 1093-RP project that reports on the progress during the scheduled Phase II effort. In this report, we present: (1) the data sets identified and acquired required for the analysis; ...
Determining Long-Term Performance of Cool Storage Systems from Short-Term Tests; Literature Review, Preliminary Methodology Description, and Final Site Selection (Final Revision of Nov. 1997 Report)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1998)
This preliminary report contains the literature review, a preliminary description of the methodologies that have been chosen for the project and final site selection recommendations for ASHRAE Research Project RP 1004 ~ ...
Energy Analysis, Baselining and Modeling of Prairie View A&M University
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1998)
Analysis of the available data found that electricity savings in the J.B. Coleman Library for June - September, 1998 were 298 MWh, or 38% of the baseline consumption during these months. Extrapolation of these savings to ...
Monitoring and Reporting Services for the Toronto Library, Final Report, TESCOR Energy Services, through Energy Systems Associates and New Horizons Technology
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1998)
This report summarizes the work performed for TESCOR Energy Services through Energy Systems Associates and New Horizons Technology. This work includes the monitoring and analysis of data from the data logger that was ...
Test Report for Low Water Consumption Stainless Steel Water Closet Toilets
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
Two stainless steel toilets using the 1.6 gallon per flush valve were tested and are documented in this report. One toilet is a version of the existing TDC water closet design (designated TDC5) and represents a retrofit ...
Phase A: Initial Development of an Advanced Diagnostic Procedure for Air-Side Retrofits in Commercial Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
The objective of this research is to develop a diagnostic approach that involves analyzing monitored whole-building cooling and heating energy use in large commercial buildings in order to determine the effectiveness of ...
Potential Energy Savings from Optimized Schedule and Economizer Cycles in the Moody Library at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study which was initiated in order to estimate the potential energy savings due to optimizing the HVAC operation schedule and using economizer cycles in the Moody Library Building ...
Prairie View A&M University Whole Campus Energy Analysis
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
Prairie View A&M University started a large scale energy management program in 1987 and 1988. This
report presents an analysis of whole-campus energy consumption at the Prairie View A&M Campus where
whole-campus indices ...
Texas LoanSTAR Monitoring and Analysis Program—Monitoring and Advisory and Review Committee (January 1991)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
Savings Analysis of Utility Bills for Unmonitored Sites, Volume I: Procedures, Results, and Discussion, Texas LoanSTAR Monitoring and Analysis Program
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1995)
The Texas LoanSTAR program is an eight year, $98 million revolving loan program, funded by oil overcharge dollars, for energy conservation retrofits in Texas state, local government and school buildings. The program began ...