Application Prospect Analysis of the Surface Water Source Heat-Pump in China
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Surface water resources in China are rather abundant and it can be use as the heat or cool source for heat pump. The winter surface water temperatures of 17 typical cities are investigated in December, and they are all ...
Impact of Indoor Environment Improvement on Comfort and Productivity in a Chipboard Workplace
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
A real example was investigated on the relationship between indoor environment, comfort and productivity in a chipboard workplace location in southern China. In this field study, a subjective evaluation and objective ...
Study of the Heating Load of a Manufactured Space with a Gas-fired Radiant Heating System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
A thermal balance mathematics model of a manufactured space with a gas-fired radiant heating system is established to calculate the heating load. Computer programs are used to solve the model. Envelope internal surface ...
Energy Efficiency Evaluation of Guangzhou West Tower Façade System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Guangzhou West Tower is an extremely tall public building. The energy efficiency evaluation of its façade should be different than that of ordinary public buildings. Based on the national code GB50189-2005, “Design Standard ...
Analysis of the Energy-Saving Potential of a Three-Rotary Wheel Fresh Air-Handling Unit
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
To evaluate the energy-saving potential of a proposed three-rotary wheel fresh air-handling unit (TRWFAHU), it is numerically simulated with weather data of Changsha by using a mathematical model. Compared with a conventional ...
Reducing Air-Conditioning System Energy Using a PMV Index
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
The control system of central air-conditioning, based on PMV, not only improves thermal comfort but also reduces system energy consumption. A new thermal comfort degree softsensor model is built via use of the CMAC neural ...
Experiment on Residential Ventilation System In Actual House
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Traced-gas was used in the experiment in order to evaluate the ventilation effect in different conditions in actual house. The influence of interior doors which opened or closed and vents position were considered in the ...
Comparison of Two Ventilation Systems in a Chinese Commercial Kitchen
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
A numerical simulation of an indoor thermal environment in a Chinese commercial kitchen has been carried out using indoor zero-equation turbulence model. Two different ventilation systems in a Chinese commercial kitchen ...
Comprehensive Evaluation Model of Building Energy Efficiency Based on Rough Sets Theory
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
In order to improve the objectivity of building energy efficiency evaluation, this paper uses a new method to evaluate building energy efficiency on the basis of rough sets theory. The contribution of different subentry ...
The Study on Thermal Performance and Applicability of Energy-saving Wall Materials in Hot Summer and Cold Winter Zones
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
The hot summer and cold winter zone is a transition zone between the cold zone and hot zone, sweltering in summer and chilly in winter, of which climate is worse. In recent years, with people's raised requirements on indoor ...