Personal Computer-Based Model for Cool Storage Performance Simulation
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
A personal computer based hourly
simulation model was developed based on the
CBS/ICE routines in the DOE-2.1 mainframe
building simulation software. The menu
driven new model employs more efficient data
and information ...
Model Code for the Control of Residential HVAC Distribution System Leakage and HVAC-Induced Building Leakage
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
Modifications to local and state codes are seen as an
appropriate strategy for the prevention of residential air
distribution system leakage and its impacts. A model code
element has been developed to assist this ...
The Potential of Energy Management and Control Systems for Real-Time Electricity Pricing Programs
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
In implementing an integrated electric utility network, direct
communication between the utility and customers is an
important component. The rapid penetration of computer
building control technology in larger commercial ...
Building Envelope Design/Retrofit Utilizing Fresnel Type Overhangs in Hot Climates
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
The selection of exterior elements for control of
solar incidence has been a major concern for
engineers, architects, and lighting designers.
This concern relates to problems of thermal heat
gain, direct glare and veiling ...
Using Mentor, an Expert System, to Perform Preventative Maintenance and Diagnostics on Centrifugal Chillers
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
Mentor is an expert system which was developed and
introduced in 1986 assists service refrigeration techs to perform
the correct preventative maintenance (PM) and diagnostics on
centrifugal chillers at the right time. This ...
Metering and Calibration in LoanSTAR Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
End-use metering in commercial buildings often
requires installation of a large variety of transducers and data
loggers. The metering installation group in the LoanSTAR
monitoring program has the primary responsibility for ...
Regional Production Economics for Ethylene and Propylene Derivatives
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1990-06)
Many developing countries have
implemented aggresslve programs to develop domestic petrochemical capacity. In those regions with abundant, low cost feedstocks, the competitive advantage seems obvious. However, other regions ...
Reliability Criteria For Turbine Shaft Based On Coupling Type - Geared To Have Flexibility.
(Texas A&M University. Turbomachinery Laboratories, 1990)
A turbine shaft end at the coupling is exposed not only to constant torque load but to various variable loads as well. These externally imposed variable loads come from sources like compressor surge, misalignment between ...
Recent Case Histories With Coupling Enclosures.
(Texas A&M University. Turbomachinery Laboratories, 1990)
Coupling enclosures are oil-tight guards which serve the double purpose of protecting people from the rotating coupling and returning oil that escapes past the seals back to the oil reservoir. Enclosures were, and still ...
The Texas LoanSTAR Program: Acquiring and Archiving LoanSTAR Data
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
This paper discusses the acquisition and archiving of data for the
Texas LoanSTAR monitoring program, an eight year, $98
million revolving loan program for energy conservation retrofits
in Texas state, local government and ...