Browsing by Subject "ASHRAE"
Now showing items 1-17 of 17
-
(2020-12-04)Performance enhancements of HVAC systems are paramount for designers and manufacturers, as HVAC accounts for nearly 50% of energy use in the United States. Building energy reductions mandated by ASHRAE standards have raised ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)ASHRAE, CIBSE and USGBC are developing a standardized, consistent set of protocols to facilitate the comparison of the measured performance of buildings, especially those claimed to be green, sustainable, and/or high ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)This is a draft of the Final Report in the ASHRAE RP-1093 project that, first summarizes the work completed during the scheduled Phase I and Phase II (presented to the PMSC in Seattle - June 1999, and Dallas February 2000), ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)This is the final report for the ASHRAE 1093-RP project. This report presents the method used to derive the diversity factors and typical load shapes of lighting and receptacle loads in office buildings. In this report the ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)This is the second report of the ASHRAE 1093-RP project that reports on the progress during the scheduled Phase II effort. In this report, we present: (1) the data sets identified and acquired required for the analysis; ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1987)A series of tests were performed to assesses the dehumidifying performance of residential central air conditioners (CACs). The performance studies were based on factors such as: (i) dynamic performance (ii) the ASHRAE ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)This is the final report for ASHRAE Research Project 1004-RP: Determining Long-Term Performance of Cool Storage Systems from Short-Term Tests. This report presents the results of the development and application of the ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)This is the Spring 1999 progress report on ASHRAE Research Project RP 1004: Determining Long-Term Performance of Cool Storage Systems from Short-Term Tests. This report presents an update concerning the work that has been ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1997)This is the preliminary report contains the literature review and site selection recommendations for ASHRAE Research Project RP 1004 — "Determining Long-term Performance of Cool Storage Systems From Short-term Tests".
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1998)This preliminary report contains the literature review, a preliminary description of the methodologies that have been chosen for the project and final site selection recommendations for ASHRAE Research Project RP 1004 ~ ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)This is the detailed test report for the ASHRAE 1050-RP project. This report presents the detailed results of the testing of IMT (Inverse Modeling Toolkit). Two kinds of testing were performed, bounds testing and accuracy ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1987)The energy use of the Texas Youth Commission/Texas Rehabilitation Commission (TYC/TRC) Building at Austin, Texas, was analyzed using the DOE 2.IB building energy simulation program. An analysis was made for the building ...
-
Fluctuations in ASHRAE Refrigerant Physical Properties and the Effect on Single and Two Phase Flow (2014-11-17)Throughout the course of the American Society of Heating Refrigeration and Air Conditioning, data of refrigerant physical properties have been published in their Handbooks. However, this information is not constant, rather ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)In this literature review, seventy two (72) articles were reviewed from various sources, including: the literature compiled by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE); literature ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)This report reviews the reported uncertainty of ASHRAE’s Inverse Model Toolkit (IMT) analysis method and the linear, and change-point linear algorithms that it uses by reviewing the published literature on the related ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)
-
(2010-10-12)The Psychrometric Testing Facility at the Riverside Energy Efficiency Laboratory at Texas AandM University has not been operational for several years. The goal of this project was to restore the testing facility to a fully ...