Now showing items 1-2 of 2

    • Kuppa, Sridhar; Baer, Heinrich (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2021)
      Dry Screw Compressor experienced HH axial displacement trip within 15 minutes after every cold start-upsince the MMS system upgrade in 2016• Failed attempt to successfully restart this compressor after every planned ...
    • Kuppa, Sridhar (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2021)
      A hydrogen compressor experienced intermittent vibration spikes during operation Review of the vibration plots revealed that the spikes appear at 11x running speed of the compressor The no of vanes of the impeller is 11 ...