Freeman, Raymond (Mary Kay O'Connor Process Safety Center; Texas &M University. Libraries, 2017)The IEC 61511 standard requires a verification calculation that a proposed design for a safety instrumented function (SIF) achieves the desired safety integrity level (SIL). The evaluation of the safety integrity level of ...