Now showing items 1-6 of 6

    • Gad, Amr; Deshpande, Atul (Texas A&M University. Turbomachinery Laboratories, 2012)
    • Khader, Ameer; Deshpande, Atul; White, Nicholas; Abdelghafour, Mohamed (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2015)
      Oil and Gas industry end users have generally approached the topic of centrifugal compressor performance estimation with little consideration to the effect of process gas conditions. This is customary since end users depend ...
    • Deshpande, Atul; Rojas, Luis; Venkatachallam, V.; Chelghoum, Mustapha (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2013)
      Summary: After a planned Shutdown and transfer valve replacement, Propane unit -GT Fr7AE DLN1- started; Unit failed to transfer to pre-mix steady state Mode (PMSS) and Trip. 05 Days of online troubleshooting using Fishbone ...
    • Wakileh, Basel; Al-Dossari, Nawaf; Deshpande, Atul (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2015)
    • Basel, Wakileh; Rahimi, Adel; Eranki, Auditya; Deshpande, Atul; Hasnan, Nasir (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2013)
    • Sonavane, Pradip; Deshpande, Atul; Chirathadam, Thomas; Simmons, Harold (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2015)
      RasGas LNG Trains-1 and 2, comprising of three refrigeration centrifugal compressors each, were commissioned in 1999 and 2000, respectively. Three compressors have achieved 15 years of trouble free operation through ...