Now showing items 1-2 of 2

    • Cich, Stefan; Moore, Jeff; Day-Towler, Meera (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station; Texas A & M University. Libraries, [2019])
      During the testing of a 1 MWe power loop with super critical co2, it was discovered that dry ice formation across dry gas seals would be an issue. This case study looks at the negative effects of dry ice formation and how ...
    • Sandberg, Mark; Kurtz, Rainer; McWhirter, Jeff; Day-Towler, Meera; Downing, David; Weatherwax, Mark (Turbomachinery Laboratory; Texas A&M Engineering Experiment Station; Texas A & M University. Libraries, [2019])
      Surge Detection Logic - Trip or not on Surge Detection? Compressor Control Redundancy Requirements Is the primary purpose of an anti-surge valve a control or protection? Check valve locations and their impact on ...