    • Hingorani, A.; Pavlov, A. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)
      Energy use in compressed air systems accounts for typically 10% of the total industrial electricity consumption. It also accounts for close to 99% of the CO2 footprint of an air compressor and approximately 80% of the life ...
    • Keunecke, G.; Mitchem, C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1982)
      Developments in catalyst technology have played a major role implementing phthalic anhydride process improvements. Steam turbines yield large energy savings, and are flexible in achieving a process heat/energy balance. ...
    • McEver, R. M. Jr. (Energy Systems Laboratory (http://esl.tamu.edu), 1986-06)
      Universities, hospitals and similar institutions, as well as manufacturers and plants have implemented programs of utility submetering. Submetering of utilities is defined as the measurement of energy at or near the ...
    • Robinson, A. M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1984)
      Energy Management and Conservation have become mutually inclusive in operation of today's petrochemical plants. This presentation shows how the efficient conversion and distribution of energy and the efficient energy ...
    • McKee, H. B.; Kympton, H. W.; Arnold, J. W.; Paisan, J. J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1980)
      The design, operating characteristics, and energy savings from an energy recovery system employed on a potato chip fryer which became operational in December, 1979, is discussed. The design incorporates a modification to ...
    • Reynolds, J. A. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1980)
      The current cost of electrical power is translated into an annualized value to be used for economic considerations in the selection of pumping equipment. Motor sizing guidelines are suggested to permit electric motors to ...
    • Udall, H. N. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1983)
      High-Frequency electric resistance heating systems have been widely used for many years for both welding and heat treating. In the past the major reason for using High-Frequency heating processes has been because of their ...
    • Davis, R. C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1984)
      Absorption refrigeration technology can be an economical and cost effective means of reducing energy cost and/or improving the efficiency and output of your process. We believe the potential benefits of absorption refrigeration ...
    • Nelson, R. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1982)
      The low cost of steam combined with the maintenance free operation of steam ejectors has assured their unquestioned use in providing the necessary vacuum for crude distillation vacuum towers. However, the cost of steam ...
    • Lingousky, J. E.; McKay, J. R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1983)
      In 1982, 6.9 million BOE of energy costing nearly $600 million was used in approximately 16,000 Bell System Telephone equipment buildings. About 27% of that energy was used for heating, ventilating and air conditioning. ...
    • Simonetti, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)
      Water evaporates spontaneously in contact with the air, absorbing around 680 W/(kg/h of evaporated water) from the air (1,053 BTU/lb.). Direct Evaporative Cooling (DEC) exploits this simple physical phenomenon to achieve ...
    • Lubbeck, W. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1982)
      Arc furnace melting which at one time was almost exclusively used to produce alloy steel and steel castings is now widely accepted in the industry as an efficient process to produce all types of steel and iron. Presently, ...
    • Claridge, D. E.; Baltazar-Cervantes, J. C.; Zhu, Y. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
      This report presents the energy and dollar savings for the period July 2000 - June 2001 for 12 Dallas County facilities that have been retrofit by Enershop. The savings for this period total $745,046, which represent 73.2% ...
    • James, B. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1982)
      The changing role of energy as a production input in the industrial sector in Canada is examined. Energy use patterns are reviewed in terms of the energy input types, both purchased and self-produced, the actual energy ...
    • Liu, Z.; Sweeny, J.; Song, S.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), 2005-03)
    • Stanton, E. H. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1980)
      The potential for recovering energy from low pressure furnace flue products is limited when standard heat recovery equipment is utilized. Efficient energy recovery can be accomplished by providing a flue gas side pressure ...
    • Monroe, R. C. (Energy Systems Laboratory (http://esl.tamu.edu), 1985-05)
      Axial fans are used for thousands of industrial applications consuming millions of kilowatts daily. The decision that saves dollars is to either automatically change fan speed or change blade pitch to save up to 50 percent ...
    • Jansen, P. R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1984)
      In efforts to reduce operating costs, the IBM site at Kingston, New York incorporated the energy saving concept of 'free cooling' (direct cooling of chilled water with condenser water) with the expansion of the site chilled ...
    • Niess, R. C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1983)
      The widespread use of geothermal energy to reduce heating costs has been limited in part by the high initial cost of digging deep wells to obtain moderate temperature water (under 220 F) for direct-use industrial process ...
    • Sobczak, N. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1981)
      With the evolution of the Building Automation System industry there has been an increasing emphasis on the development and utilization of complex energy saving and control features. The complexity of this operation has ...