dc.description.abstractThe purpose of this study was to determine how well the Monte Carlo transport code FLUKA can simulate a tissue-equivalent proportional counter (TEPC) and produce the expected delta ray events when exposed to high energy heavy ions (HZE) like in the galactic cosmic ray (GCR) environment. Accurate transport codes are desirable because of the high cost of beam time, the inability to measure the mixed field GCR on the ground and the flexibility they offer in the engineering and design process. A spherical TEPC simulating a 1 um site size was constructed in FLUKA and its response was compared to experimental data for an 56Fe beam at 360 MeV/nucleon. The response of several narrow beams at different impact parameters were used to explain the features of the response of the same detector exposed to a uniform field of radiation. Additionally, an investigation was made into the effect of the wall thickness on the response of the TEPC and the range of delta rays in the tissue-equivalent (TE) wall material. A full impact parameter test (from IP = 0 to IP = detector radius) was performed to show that FLUKA produces the expected wall effect. That is, energy deposition in the gas volume can occur even when the primary beam does not pass through the gas volume. A final comparison to experimental data was made for the simulated TEPC exposed to various broad beams in the energy range of 200 - 1000 MeV/nucleon. FLUKA overestimated energy deposition in the gas volume in all cases. The FLUKA results differed from the experimental data by an average of 25.2 % for yF and 12.4 % for yD. It is suggested that this difference can be reduced by adjusting the FLUKA default ionization potential and density correction factors.en
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.subjectmicrodosimetryen
dc.subjecttissue-equivalent proportional counteren
dc.subjectgalactic cosmic rayen
dc.subjectFLUKAen
dc.titleSimulation and Analysis of a Tissue Equivalent Proportional Counter Using the Monte Carlo Transport Code FLUKAen
dc.typeThesisen
thesis.degree.departmentNuclear Engineeringen
thesis.degree.disciplineHealth Physicsen
thesis.degree.grantorTexas A&M Universityen
thesis.degree.nameMaster of Scienceen
thesis.degree.levelMastersen
dc.contributor.committeeMemberBraby, Leslie A.
dc.contributor.committeeMemberJackson, Katherine M.
dc.type.genrethesisen
dc.type.materialtexten


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record