Development of Empirical Temperature and Humidity-Based Degraded-Condition Indicators for Low-Tonnage Air Conditioners

Thumbnail Image

Date

1997

Journal Title

Journal ISSN

Volume Title

Publisher

Texas A&M University

Abstract

A split-system direct-expansion air conditioner was used to empirically determine temperature and return-air humidity indicators that could detect performance degradation resulting from degraded conditions. The air conditioner test bench was equipped with the ability to use either a short-tube orifice (STO) or a thermal expansion valve (TXV). The degraded conditions studied include low evaporator airflow, high and low-charge, and a blocked condenser coil. The work presented in this thesis is experimentally based which could identify degraded effects that fall outside of a simulation-based approach. It sought to utilize only low-cost temperature sensing means, although return-air humidity was an important factor for obtaining early detection over a wide range of operating conditions. It was empirically based rather than model based to reduce computation time with a real-time processor. Further, the current work differentiated between a system that uses a shorttube orifice (STO), or fixed-orifice expansion, and a system that uses a thermal expansion valve (TXV), or variable-orifice expansion. This thesis shows that low-cost temperature sensors could be used to detect the degraded conditions studied. However, it is also shown that indicators of low evaporator airflow depend on three loading factors; outdoor-air temperature, return-air temperature, and return-air humidity. In the literature, the humidity sensing point has been neglected by automated detection systems for failures and degraded conditions of low-tonnage air conditioners. The effects of the loading factors on the indicators relative to improper charge and a blocked condenser coil were not studied. STO system and a TXV system relative to the degradations studied, a common set of indicators was identified that could detect degraded conditions without regard to the expansion device.

Description

Due to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the item.
Includes bibliographical references: p.165-171.
Issued also on microfiche from Lange Micrographics.

Keywords

mechanical engineering., Major mechanical engineering.

Citation