Abstract
Final end uses of steam include two major classifications: those uses that condense the steam against heat transfer surfaces to provide heat to an item of process or service equipment; and those that require a mass flow of steam for stripping, dilution, a reaction ingredient, etc. These classifications are termed 'Btu' loads or 'Pound' loads. Some final end uses of steam are actually a combination of the two.
The classification of steam loads is extremely important to the overall economics of the industrial plant steam system. These economic effects are explained in detail as they impact on both the thermal efficiency and the heat power cycle efficiency of an industrial system. The use of a powerful steam system mass and energy modeling program called MESA (Modular Energy System Analyzer, The MESA Company) in identifying and accurately evaluating these effects is described.
Collections
Citation
Waterland, A. F. (1983). Industrial Steam Power Cycles Final End-Use Classification. Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu). Available electronically from https : / /hdl .handle .net /1969 .1 /94580.