Show simple item record

Visit the Energy Systems Laboratory Homepage.

dc.creatorWithers, C.
dc.creatorMoyer, N.
dc.creatorChasar, D.
dc.creatorChandra, S.
dc.date.accessioned2007-04-19T19:01:43Z
dc.date.available2007-04-19T19:01:43Z
dc.date.issued2002
dc.identifier.otherESL-HH-02-05-39
dc.identifier.urihttps://hdl.handle.net/1969.1/4590
dc.description.abstractTwo nearly identical houses situated next to each other in Bossier City, Louisiana were studied in an effort to better understand moisture and cooling energy related problems in manufactured houses with low thermostat set-points during the cooling season. By design, the major difference between houses was the type of air conditioning units. House A had a standard split air conditioner and House B had a twospeed split air conditioner. In an effort to make the buildings more similar, the building airtightness was adjusted until it was the same in each house, and duct leaks were sealed so that the ducts were tight and there was equal tightness in both houses. A ventilation system was also added at the same time of duct repair. Duct repair and the ventilation modifications resulted in significant impacts on the cooling energy, temperature, relative humidity, and building pressures. Cooling energy decreased 37% in House A and 18% in House B, while the floor space dewpoint increased significantly. It is estimated that 35 % savings was due solely to duct repair in House A and 17% in House B. The primary cause of House A savings being twice House B is attributed to House A operating at nearly twice the capacity most of the time and had more duct leakage repaired. This resulted in higher system pressures and therefore greater duct leakage than in House B. Before building modifications, House A used 15.4 kWh per day (32%) more than House B and 3.4 kWh per day (11%) more after modifications. A method of characterizing interstitial spaces using dewpoint measurement is presented and shows that the belly space became 2.6 times more like outdoor conditions after repairs in House A and 2.0 times more in House B.en
dc.format.extent935720 bytesen
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherEnergy Systems Laboratory (http://esl.tamu.edu)
dc.publisherTexas A&M University (http://www.tamu.edu)
dc.titlePerformance and Impact from Duct Repair and Ventilation Modifications of Two Newly Constructed Manufactured Houses Located in a Hot and Humid Climateen


This item appears in the following Collection(s)

Show simple item record