Monitored Energy Use Patterns in Low-Income Housing in a Hot and Humid Climate
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
The Florida Solar Energy Center (FSEC) is
metering energy use in two Habitat for Humanity
developments. The objective is to understand how
energy is used in low income housing and how it can
be effectively reduced.
The ten ...
Measured Energy Savings from Retrofits Installed in Low-Income Housing in a Hot and Humid Climate
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
The Florida Solar Energy Center (FSEC) is metering
energy use in a Habitat for Humanity housing
development. The objective is to understand the way
in which energy is used in low income housing and
how it can be effectively ...
Influence of Attic Radiant Barrier Systems on Air Conditioning Demand in an Utility Pilot Project
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
A utility monitoring project has evaluated radiant
barrier systems (RBS) as a new potential demand site
management (DSM) program. The study examined
how the retrofit of attic radiant barriers can be
expected to alter utility ...
FLASTAR: Measured Savings of a Comprehensive Energy Retrofit in a Florida Elementary School
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
This paper describes the final results for the pilot
demonstration of the Florida Public Building Loan
Concept. This loan program was intended to provide
low cost funds to eligible public entities for upgrade
of building ...
Impact of Reflective Roofing on Cooling Electrical Use and Peak Demand in a Florida Retail Mall
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Architects in hot climates have long recognized
that reflective roof colors can reduce building cooling
load. Experimentation spanning nearly three decades
has shown that white roofing surfaces can
significantly reduce ...
Performance Assessment of Photovoltaic Attic Ventilator Fans
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
Controlling summer attic heat gain is important to reducing air conditioning energy use in homes in hot-humid climates. Both heat transfer through ceilings and t attic duct systems can make up a large part of peak cooling ...