Innovative Method for Performance Inspections often save 20-30% through Optimization of Air-Conditioning and Refrigeration
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
Air-conditioning, refrigeration and heat pump equipment is using 15 to 20% of the electrical energy globally. Many times these systems do not operate in an effective way. The paper present a method for and experience from ...
IAQ in Hospitals - Better Health through Indoor Air Quality Awareness
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
Quality air is fundamental to people's health and well-being. Indoor air quality is an important issue from both a social and economic point of view. Continual advances in medicine and technology necessitate constant ...
Proposal for an Adsorption Solar-Driven Air-Conditioning Unit for Public Offices
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
A simple prototype air conditioning unit driven entirely by solar energy is proposed aiming at replacing the conventional vapor compression air conditioning systems which are reasonable for the global warming. The proposed ...
Exploring the Optimal Thermal Mass to Investigate the Potential of a Novel Low-Energy House Concept
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
In conventional buildings thermal mass is a permanent building characteristic depending on the building design. However, none of the permanent thermal mass concepts are optimal in all operational conditions. We propose a ...
Predicted vs. Actual Energy Savings of Retrofitted House
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
This paper reports the results of actual energy savings and the predicted energy savings of retrofitted one-story house located in Dhahran, Saudi Arabia. The process started with modeling the house prior to retrofitting ...
Opportunities of Conserving Energy on an Existing Institutional Building: Case Study
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
The building considered in this case study is a two-story facility with total floor area of 3588 square meter; it is mainly educational facility (classrooms, laboratories, and workshops) as well as staff offices. The ...
Importance of Measurement: The Impact of Power Quality in Energy Efficiency
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
To implement sustainable and green initiatives in a building it is vital to have a means of measuring and verifying its performance. This is done by the introduction of intelligent utility and energy metering to the facility ...
Energy Efficient Retrofits and Green Building Practices
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
According to the recent survey more and more concern being expressed throughout the Middle East regions that the power generation companies are suffering with shortage of power during the peek hours and consequently unable ...
Green Buildings: Principles, Practices and Techniques, The French "HQE" Versus the American "LEED"
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-10)
Buildings account for a large amount of land use, energy and water consumption, in addition to air and atmosphere alteration. Considering the statistics and the impact of the built environment on human health as well as ...
Thermal Performance of Exposed Composed Roofs in Very Hot Dry Desert Region in Egypt (Toshky)
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
Thermal performance for any building in hot dry region depend on the external climatic factor, the ability of the construction materials used in gained heat through day time and loss this heat through night time through ...