Now showing items 1849-1868 of 4398
-
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1990-06)The high level of current profitability within the petrochemical industry has spurred an unprecedented number of announcements of new global capacity. Many of the announcements have been made by organizations with no ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)In recent years, there has been a growing interest to include passive concepts in buildings as a design strategy for achieving energy efficiency and optimum indoor thermal comfort in workspace as well. The paper attempts ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)School classroom space-conditioning equipment in hot and humid climates is often excessively burdened by the requirement to dehumidify incoming air to maintain proper thermal comfort and air quality. To that end, application of ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1986)The Residential Good Cents Program is a program designed to reduce energy use and electrical demand of residences. It was introduced to residential developers and contractors in the Spring of 1983 in the Central Power and ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)An independent field research effort co-funded by the Gas Research Institute and The U.S. Department of Energy (DOE) Oak Ridge National Laboratory is documenting the performance and energy usage characteristics of active ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)Heating energy consumption in winter is an important component of the whole building energy consumption in the severe cold zone in north China. This paper presents a heating water system of a hotel building in Harbin, ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1985)This paper discusses cooling energy use in a small office building with the objective of developing an understanding of where energy is used and identifying relationships between cooling energy and other energy end uses. ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)A nominal 10.6 kW (3 ton), vertical-configuration ground-coupled heat pump was installed in Abilene, Texas in December 1989 and was monitored until May 1993 using a remote data acquisition system. The unit was installed ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)Two field studies were conducted in a university classroom in the autumn of 2004 in Harbin. The objective of these studies was to assess the thermal conditions and the subjective effects on occupant thermal comfort. A field ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1980)The University of Tennessee is one of three universities selected by the Industrial Energy Conservation Program of the Department of Energy to develop and demonstrate the concept of an Energy Analysis and Diagnostics Center ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)The American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) Transfer Function Method (TFM) was validated using two identical wood frame residential-type structures, each containing an east and ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 1999-05)Detailed field measurements of energy consumption (kWh) and demand (kW) are conducted on two injection molding machines (IMMs) used in a typical plastic manufacturing facility in the San Francisco Bay Area, with/without ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 1986-06)The high heat value of the plant's treated wastewater gave the economic edge to electric space conditioning, the major driver critical to the sale of the all-electric combination of space conditioning, lighting and ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
-
(Energy Systems Laboratory, 2011)
-
(Energy Systems Laboratory, 2011)
-
Financial Impact of Good Condenser Vacuum in Industrial Steam Turbines: Computer Modeling Techniques (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1984)Industrial turbine throttle conditions are fixed by plant designs - materials of construction, steam requirements, etc. Condensing turbine exhaust conditions are limited by the atmosphere to which residual heat is rejected; ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1982)The 1980's will be a decade of intense adjustment by busine3s to the cost of money and energy. American Industry will require enormous amounts of capital for energy conservation to remain competitive. However, the average ...