Search
Now showing items 1-6 of 6
Analysis of Energy Conservation Options for USDOE Child Development Center
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
The Child Development Center (CDC) was designed to be a "showpiece" model building. Its construction included energy efficient features, including a photovoltaic system, solar hot water system, energy efficient lighting, ...
Compilation of Diversity Factors and Schedules for Energy and Cooling Load Calculations, Phase II Report - Identified Relevant Data Sets, Methods, and Variability Analysis
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)
This is the second report of the ASHRAE 1093-RP project that reports on the progress during the scheduled Phase II effort. In this report, we present: (1) the data sets identified and acquired required for the analysis; ...
Energy Analysis, Baselining and Modeling of Prairie View A&M University
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1998)
Analysis of the available data found that electricity savings in the J.B. Coleman Library for June - September, 1998 were 298 MWh, or 38% of the baseline consumption during these months. Extrapolation of these savings to ...
Estimated Savings from Turning Off Unnecessary Electrical Loads During Unoccupied Periods at the Langford Architecture Center
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1996)
This report presents the results of an on-off test conducted to determine the lighting load in the studios on the third and fourth floors of the Langford Architecture Center Building A and the savings that would be achieved ...
Analysis of Energy Conservation Options for USDOE Child Development Center, Final Summary Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
The U.S.D.O.E. Forrestal Child Development Center (CDC) was designed to be a "showpiece" model building. Its construction included energy efficient features such as efficient lighting, a photovoltaic system, an energy ...
Lighting Survey Results at the Langford Architecture Center and Estimated Savings by Delamping
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1997)
This report presents the results of a survey conducted to measure the illuminance levels in all rooms in the Langford Architecture Center buildings. The purpose of this survey was to investigate which rooms are over ...