A Case Study of Continuous Commissioning of the VAV System in China
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
This paper introduces a continuous commissioning of the VAV system in a real building in China. On the base of nearly one year's testing data, the energy conservation level of the project is analyzed, and significance of ...
Blackland Pastures: Suggestions for Their Improvement and Establishment.
(Texas Agricultural Extension Service, 1947)
Mechanical Air Distribution and Interacting Relationships
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1989)
It has been determined from extensive
testing conducted between May 1987 and May
1988, in the hot and humid climate of
central Florida, that pressure differences
within the envelope of residential housing
exists. These can ...
Independent Control of Sensible and Latent Cooling in Small Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1989)
This paper presents salient results of a utility-sponsored research project whose major objective was to identify all-electric technical means for energy-efficient independent control of sensible and latent cooling in ...
Screening Tool for Desiccant Dehumidification Applications
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
A state-of-the-art software tool that
calculates the benefits of desiccant-based air-treatment
equipment is described. The software, a
Desiccant Systems Application Screening Tool, is
written in the WindowsTM environment ...
Impacts of Water Loop Management on Simultaneous Heating and Cooling in Coupled Control Air Handling Units
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
The impacts of the water loop management
on the heating and cooling energy consumption
are investigated by using model simulation. The
simulation results show that the total thermal
energy consumption can be increased by ...
Cooling Tower Considerations for Energy Optimizations
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1986)
Energy conservation strategies and production
economies involve more than examining the
cooling tower fan consumption of horse power.
Colder water provides vast potentials for
savings. Ask yourself, "What is the dollar
and ...
The Influence of Residential Solar Water Heating on Electric Utility Demand
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
Similar sets of residences in Austin, Texas with electric water heaters and solar water heaters with electric back-up were monitored during 1982 to determine their instantaneous electric demands, the purpose being to ...
Measurements and Comparisons of Sunlighted and North-Lighted Atriums on Two Office Buildings in Dallas, Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1986)
The use of natural light (daylighting) in the
atriums of office buildings is often done to
supplement or eliminate the artificial lighting
otherwise required. To the extent that the
daylight can be effectively admitted and ...
Economical Analysis of a Groundwater Source Heat Pump with Water Thermal Storage System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
The paper is based on a chilled and heat source for the building which has a total area of 140000m2 in the suburb of Beijing. By comparing the groundwater source heat pump of water thermal storage (GHPWTS) with a conventional ...