Chiller Start/Stop Optimization for a Campus-wide Chilled Water System with a Thermal Storage Tank Under a Four-Period Electricity Rate Schedule
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
The existence of a 1.4-million-gallon
chilled water thermal storage tank greatly
increases the operational flexibility of a campuswide
chilled water system under a four-part
electricity rate structure. While significant
...
A Method for Simulating Heat Recovery Systems Using AirModel in Implementations of the ASHRAE Simplified Energy Analysis Procedure
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2005)
Replacing Inefficient Equipment - An Engineering Analysis to Justify Purchasing A More Efficient Chiller
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2005)
Baseline Report for the Fort Hood Army Base: Sept. 1, 2001 To Aug. 31, 2002
(2002-12)
This report presents electricity, natural gas and cooling baselines for the thermal plant,
buildings located in the 87000 block, and the III Corp building at Ft. Hood. A baseline
analysis is also presented for the natural ...
CC® of Retrofitted, Renovated, and Rented Systems and Equipment in Utilities Plants
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2005)
Exploring Maximum Humidity Control and Energy Conservation Opportunities with Single Duct Single Zone Air-Handling Units
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Humidity control for single-duct single-zone (SDSZ) constant volume air handling units is known to be a challenge. The operation of these systems is governed by space temperature only. Under mild weather conditions, discharge ...
Sustainability Assessment of the Robert E. Johnson State Office Building, Final Report, Revised April 2002
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)
The Robert E. Johnson State (REJ) Office building is a 5-story, 303,389 square foot office building for state legislative support staff, including Legislative House Committees, Legislative Council, State Auditor, the ...
Texas’ Senate Bill 5 Legislation for Reducing Pollution in Non-Attainment and Affected Areas: Procedures for Measuring Electricity Savings from the Adoption of the International Energy Conservation Code (IRC/IECC 2001) in New Residences
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)
Four areas in Texas have been designated by the EPA as non-attainment areas because ozone levels exceed the NAAQS maximum allowable limits, Beaumont-Port Arthur, El Paso, Dallas-Ft. Worth, and Houston-Galveston-Brazoria. ...
Airside Economizer- Comparing Different Control Strategies and Common Misconceptions
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)
Air-side economizer is broadly adopted in building HVAC design and operations. When the system is properly designed and the control sequence is properly implemented, air-side economizer provides significant energy savings. ...
Texas' Senate Bill 5 Legislation for Reducing Pollution in Non-Attainment and Affected Areas: Procedures for Measuring Electricity Savings from the Adoption of the International Energy Conservation Code (IRC/IECC 2001) in New Residences
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Four areas in Texas have been designated by the
EPA as non-attainment areas because ozone levels
exceed the NAAQS maximum allowable limits,
Beaumont-Port Arthur, El Paso, Dallas-Ft. Worth,
and Houston-Galveston-Brazoria. ...