Search
Now showing items 1-10 of 28
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP) Volume II- Technical Report
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-12)
Description and Comparison of the Results of the Proposed House: Habitat for Humanity at Frazier Court, Dallas, Texas, with the 2004 IECC Standard Reference House
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-09)
The Energy Systems Laboratory was requested to calculate the emissions reductions associated
with the Habitat for Humanity Housing Project at Frazier Court, Dallas Texas. This report presents the
results of the required ...
A Comparative Analysis of Residential Energy Use for 2009 IECC Code Compliance and 2001 IECC Compliance with 2006 NAECA Appliance Standards for Selected Climate Zones in Texas
(Energy Systems Laboratory (Http://esl.tamu.edu), 2010-08)
This paper presents results of a comparative analysis of the electricity and natural gas savings from the implementation of 2009 International Energy Conservation Code (IECC) when compared with the 2001 IECC1 specifications ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Volume II - Technical Report, Annual Report to the Texas Commission on Environmental Quality, January 2006 - June 2007
(Energy Systems Laboratory, 2007-08)
The Energy Systems Laboratory, at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon Supp. 2002, ...
Recommendations for 15% Above-Code Energy Efficiency Measures on Implementing Houston Amendments to Single-Family Residential Buildings in Houston Texas
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)
This paper presents information about the energy saving potential for single-family residential buildings in Houston, Texas that are designed to be 15% above code. The energy efficient measures discussed in this paper were ...
Recommendations for 15% Above-Code Energy Efficiency Measures for Commercial Office Buildings
(Energy Systems Laboratory, 2008-11)
This report presents detailed information about the recommendations for achieving 15% above-code energy performance for commercial office buildings complying with ASHRAE Standard 90.1-19991. To accomplish the 15% annual ...
Methodology for Residential Building Energy Simulations Implemented in the International Code Compliance Calculator (IC3)
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-12)
Since 2001, Texas has been proactive in initiating clean air and energy efficiency in building policies. The Texas Emissions Reduction Plan legislation (SB 5, 77TH Leg., 2001) mandates statewide adoption of energy codes, ...
Recommendations for 15% Above-Code Energy Efficiency Measures on Implementing Houston Amendments to Single-Family Buildings in Houston Texas
(2008-11)
This report presents detailed information about the analysis that was performed to calculate the energy saving potential for residential buildings in Houston. In this analysis the energy efficient measures were proposed ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Preliminary Report: Integrated NOx Emissions Savings from EE/RE Programs Statewide
(2008-08-29)
The Energy Systems Laboratory (ESL), at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon Supp. ...
Recommendations for 15% Above-Code Energy Efficiency Measures for Residential Buildings
(Energy Systems Laboratory, 2008-11)
This report presents detailed information about the recommendations for achieving 15% above-code energy performance for single-family residences. The analysis was performed using a simulation model of an International ...