Rebuild America Program – Brazos Valley Energy Conservation Coalition – Quarterly Report for July – September 1998
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1998)
The Brazos Valley Energy Conservation Coalition (BVECC), administered by the Energy Systems Laboratory (ESL) of Texas A&M University, in College Station, Texas received notification of the U.S. Department of Energy ...
Development of Baseline Monthly Utility Models for Fort Hood, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), 1996-04)
The Fort Hood Army base in central Texas has more than 5,200 buildings and can be considered as typical of large Department of Defense Army bases in the continental United States. The annual utility bill of the base exceeds ...
ASHRAE's Proposed Guideline 14P for Measurement of Energy and Demand Savings: How to Determine What Was Really Saved by the Retrofit
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
ASHRAE has recently completed the development of
Guideline 14 to fill a need for a standard set of
energy (and demand) savings calculation procedures.
Guideline 14 is intended to be a guideline that
provides a minimum ...
Improving Boiler Efficiency Modeling Based On Ambient Air Temperature
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Optimum economic operation in a large
power plant can cut operating costs substantially.
Individual plant equipment should be operated
under conditions that are most favorable for
maximizing its efficiency. It is widely ...
ASHRAE's Guideline 14-2002 for Measurement of Energy and Demand Savings: How to Determine What Was Really Saved by the Retrofit
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2005)
Reducing Building Energy Costs Using Optimized Operation Strategies for Constant Volume Air Handling Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Building energy consumption can be substantially
reduced after implementing what we call Extended
O&M Measures. The Extended O&M Measures are a
scientific refinement of traditional O&M measures.
Specifically, they ...
Measured Energy Use Indices for 27 Office Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
Energy use indices for 27 government office buildings are presented that have been assembled from hourly
monitored data as part of the Texas LoanSTAR program and other efforts at the Energy Systems Laboratory. These
indices ...
Development of Load Forecasting Procedures for the Texas A&M University System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
This paper reports on the effort to develop load-forecasting procedures for the Texas A&M University System
(TAMUS). Such procedures are being investigated to determine if the TAMUS can benefit from the pending
deregulation ...
Baseline Report for the Fort Hood Army Base: Sept. 1, 2001 To Aug. 31, 2002
(2002-12)
This report presents electricity, natural gas and cooling baselines for the thermal plant,
buildings located in the 87000 block, and the III Corp building at Ft. Hood. A baseline
analysis is also presented for the natural ...
Use of Energy Management and Control Systems for Performance Monitoring of Retrofit Projects: Final Summary Report for USDOE Office of Conservation and Energy, Final Revision, March 1993
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
Traditionally, Energy Management and Control Systems (EMCSs) have been used to control
HVAC, lighting, fire and security systems in buildings. Few EMCSs are used for long term
trending and analysis of energy use (i.e., ...