Search
Now showing items 21-30 of 45
15% Above-Code Energy Efficiency Measures for Commercial Buildings in Texas
(Energy Systems Laboratory, 2007-08)
In the pages that follow, 15% above-code measures for new commercial buildings are presented
for the 41 non-attainment and affected counties in Texas, separated by climate area. Each page
contains a description of the ...
NOx, SOx and CO2 Emissions Reduction from Continuous Commissioning® (CC®) Measures at the Rent-A-Car Facility in the Dallas-Fort Worth International Airport
(2006-10-27)
The Energy Systems Laboratory (ESL) at the Texas Engineering Experiment Station, Texas A&M University System was contracted to fulfill a Continuous Commissioning® (CC®)project on the Rent-a-Car facility (RAC) of the ...
Development of a Toolkit for Calculating Linear, Change-Point Linear and Multiple-Linear Inverse Building Energy Analysis Models, ASHRAE Research Project 1050-RP, Final Report
(Energy Systems Laboratory, Texas A&M University, 2002-11-01)
This report summarizes the results of ASHRAE Research Project 1050: Development
of a Toolkit for Calculating Linear, Change-Point Linear and Multiple Linear Inverse
Building Energy Analysis Models. The Inverse Modeling ...
Literature Review on Underfloor Air Distribution (UFAD) Systems
(2006-01-10)
Various sources and search engines were used to find the technical research and literature by using specific keywords to search for the relevant reports or browsing through the list of documents. First, the 227 of references ...
Water/Wastewater Engineering Report (High Efficiency Pump/Motor Replacement - M2 Model)
(2006-10-30)
Pumping water or wastewater is the largest use of electricity for a municipal water supply or wastewater treatment plant. Increasing the overall efficiency of the pumping system can achieve significant energy savings. ...
Literature Review of Displacement Ventilation
(Energy Systems Laboratory, Texas A&M University, 2005-05)
Various sources and search engines were used to find the technical research and literature by using specific keywords to search for the relevant reports or browsing through the list of documents. First, the 78 references ...
Description and Comparison of the Results of the Proposed House: Habitat for Humanity at Frazier Court, Dallas, Texas, with the 2004 IECC Standard Reference House
(Energy Systems Laboratiry, 2010-09)
The Energy Systems Laboratory was requested to calculate the emissions reductions associated
with the Habitat for Humanity Housing Project at Frazier Court, Dallas Texas. This report presents the
results of the required ...
Energy Use, Information, and Behavior in Small Commercial Buildings
(2009-02-20)
To explore behavioral effects on energy use in small commercial buildings, owners and
managers of 40 small businesses were interviewed. These energy decision-makers were
found to have very poor information on energy ...
Savings Report for the Fort Hood Army Base
(2005-12)
This report presents electricity consumption and electric demand savings analysis for the Thermal Plant, buildings located in the 87000 block, III Corp building and other buildings that were determined to be part of the ...
ESL Monthly Energy Consumption Report (MECR) Production Manual
(Energy Systems Laboratory (http://esl.tamu.edu), 2005-03)