Search
Now showing items 91-100 of 156
Comparison Between TRNSYS Software Simulation and F-Chart Program on Pool Heating System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2012)
The purpose of this report is to test the accuracy of TRNSYS simulation of Solar Pool Heating System by comparing with F-Chart program which is an authoritative tool to analyze solar system and was developed in 1970s.
This ...
A Simplified Residential Base-Case Model
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2013)
This study was for the DOE-2.1e program to develop a simplified residential ASHP house model in Houston, Texas. The house characteristics were based on the standard reference design and requirements as defined in Chapter ...
Energy Efficiency/Renewable Energy (EERE) Projects in Texas Public Schools
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
This paper presents the preliminary results from an analysis of the energy saving potential in new and existing Texas Independent School Districts (ISDs). The analysis was performed using a K-12 simulation model based on ...
Energy Efficiency, Cost-Effectiveness, and Air Pollutant Reduction Analysis From Energy Efficiency and Renewable Energy (EE/RE) Projects in Texas Public Schools
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
The purpose of this report is to provide the preliminary results from an analysis of the potential energy
savings, and resultant air pollution reductions associated with the energy savings from the application of
cost-effective ...
Internet Data logging and Display
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
The current energy savings technology relies on conventional data logging systems, in which two major barriers exist. Formost is the fact that retrieving the energy data is not convenient, and the cost of the data logging ...
Automated Data Quality Analysis Research and Development
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)
The Automated Data Quality process development is an effort to automate the analysis and
monitoring of the Energy Systems Lab's (ESL) polling and energy data process. Polling status
refers to basic telecommunication line ...
Sustainability Assessment of the Robert E. Johnson State Office Building, Final Report, Revised April 2002
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)
The Robert E. Johnson State (REJ) Office building is a 5-story, 303,389 square foot office building for state legislative support staff, including Legislative House Committees, Legislative Council, State Auditor, the ...
Access and Display of LoanSTAR Data via the Internet
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
The Energy and Environmental Data System (EEDS) is a web application that facilitates web-based viewing of the Energy Systems Lab's extensive building energy databases. EEDS is the initial framework for a growing set of ...
Texas’ Senate Bill 5 Legislation for Reducing Pollution in Non-Attainment and Affected Areas: Procedures for Measuring Electricity Savings from the Adoption of the International Energy Conservation Code (IRC/IECC 2001) in New Residences
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)
Four areas in Texas have been designated by the EPA as non-attainment areas because ozone levels exceed the NAAQS maximum allowable limits, Beaumont-Port Arthur, El Paso, Dallas-Ft. Worth, and Houston-Galveston-Brazoria. ...
Comfort Conditions in a Habitat for Humanity House in Central Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
This paper presents preliminary results of an
analysis of measured comfort conditions for a Habitat
for humanity house in central Texas. In the case
study house indoor-outdoor temperature, humidity
and C02 levels have been ...