Replacing Inefficient Equipment - An Engineering Analysis to Justify Purchasing A More Efficient Chiller
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2005)
Baseline Report for the Fort Hood Army Base: Sept. 1, 2001 To Aug. 31, 2002
(2002-12)
This report presents electricity, natural gas and cooling baselines for the thermal plant,
buildings located in the 87000 block, and the III Corp building at Ft. Hood. A baseline
analysis is also presented for the natural ...
CC® of Retrofitted, Renovated, and Rented Systems and Equipment in Utilities Plants
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2005)
Inclusion of Building Envelope Thermal Lag Effects in Linear Regression Models of Daily Basis Building Energy Use Data
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2012)
Retrofit Savings for Brazos County
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This report presents the energy and dollar savings for the period May 2000 - April 2001 for 10 of the Brazos County facilities that have been retrofit. The electricity use saved was 555,170 kWh and the demand was 1062 kW, ...
Energy Savings Report For Dallas County, July 2000 – June 2001
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This report presents the energy and dollar savings for the period July 2000 - June 2001 for 12 Dallas County facilities that have been retrofit by Enershop. The savings for this period total $745,046, which represent 73.2% ...
Airside Economizer- Comparing Different Control Strategies and Common Misconceptions
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)
Air-side economizer is broadly adopted in building HVAC design and operations. When the system is properly designed and the control sequence is properly implemented, air-side economizer provides significant energy savings. ...
Integrated Commissioning for a Large Medical Facility
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The energy costs of heating, ventilating and
air conditioning usually represents a large
portion of the utility bills for a medical facility.
One large, modem medical center located in the
hot and humid region of southern ...
Data Visualization for Quality-Check Purposes of Monitored Electricity Consumption in All Office Buildings in the ESL Database
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)
This report comprises an effort to visualize the monitored electricity consumption in all office buildings (not including the office buildings comprising other functions as classrooms and laboratories, for instance) in the ...
Program Overview: The Texas LoanSTAR Program; 1989-October 1999, A 10-Year Experience
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)
The Texas LoanSTAR (Loans to Save Taxes and Resources) program was conceived as a $98.6 million capital retrofit program for building energy efficiency. The funding source is petroleum violation escrow funds (PVE) from the ...