CC® of Retrofitted, Renovated, and Rented Systems and Equipment in Utilities Plants
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2005)
Retrofit Savings for Brazos County
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This report presents the energy and dollar savings for the period May 2000 - April 2001 for 10 of the Brazos County facilities that have been retrofit. The electricity use saved was 555,170 kWh and the demand was 1062 kW, ...
Energy Savings Report For Dallas County, July 2000 – June 2001
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
This report presents the energy and dollar savings for the period July 2000 - June 2001 for 12 Dallas County facilities that have been retrofit by Enershop. The savings for this period total $745,046, which represent 73.2% ...
Airside Economizer- Comparing Different Control Strategies and Common Misconceptions
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)
Air-side economizer is broadly adopted in building HVAC design and operations. When the system is properly designed and the control sequence is properly implemented, air-side economizer provides significant energy savings. ...
Integrated Commissioning for a Large Medical Facility
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The energy costs of heating, ventilating and
air conditioning usually represents a large
portion of the utility bills for a medical facility.
One large, modem medical center located in the
hot and humid region of southern ...
Data Visualization for Quality-Check Purposes of Monitored Electricity Consumption in All Office Buildings in the ESL Database
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)
This report comprises an effort to visualize the monitored electricity consumption in all office buildings (not including the office buildings comprising other functions as classrooms and laboratories, for instance) in the ...
Program Overview: The Texas LoanSTAR Program; 1989-October 1999, A 10-Year Experience
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)
The Texas LoanSTAR (Loans to Save Taxes and Resources) program was conceived as a $98.6 million capital retrofit program for building energy efficiency. The funding source is petroleum violation escrow funds (PVE) from the ...
Optimize the Supply Air Temperature Reset Schedule for a Single-Duct VAV System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The supply air temperature for a single-duct
variable air volume (VAV) system is usually set as a
constant. To minimize the simultaneous cooling and
heating, this supply temperature is often reset based
on either return ...
Lessons Learned from Continuous Commissioning of the Robert E. Johnson State Office Building, Austin, TX
(2008-09-22)
The Robert E. Johnson State Office building is a 5-story, 303,389 square foot office building built in 2000 located in downtown Austin, TX. The original building design included a number of energy conservation measures ...
Using Simulation Models for District Chilled Water Distribution Systems Design
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
The capital investment for the distribution system is often the most expensive portion of a district heating
and cooling system, which usually constitutes 50 to 70% of the total cost. Because of high initial cost, it is
very ...