Search
Now showing items 21-30 of 268
Test for Modeling Windows in DOE 2.1E for Comparing the Window Library with the Shading Coefficient Method for a Single-Family Residence in Texas
(2008-07-18)
This study examines the difference of the window simulation test between the Shading Coefficient (SC) and the Window Library (WL) Methods on DOE 2.1E of the 2000 IECC (International Energy Conservation Code) for single-family ...
Recommendations for 15% Above-Code Energy Efficiency Measures for Commercial Office Buildings
(Energy Systems Laboratory, 2008-11)
This report presents detailed information about the recommendations for achieving 15% above-code energy performance for commercial office buildings complying with ASHRAE Standard 90.1-19991. To accomplish the 15% annual ...
Bacterial Monitoring for the Buck Creek Watershed
(Texas Water Resources Institute, 2008-08)
The “Bacterial Monitoring for the Buck Creek Watershed” project was developed in response to the creek’s listing on the Texas Water Quality Inventory and 303(d) List due to a bacterial impairment and subsequent total maximum ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Volume II--Technical Report, Annual Report to the Texas Commission on Environmental Quality January 2008-December 2008
(2009-12)
The Energy Systems Laboratory, at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon Supp. 2002, ...
2009 International SWAT Conference Conference Proceedings
(Texas Water Resources Institute, 2009-08)
Recommendations for 15% Above-Code Energy Efficiency Measures for Single-Family Residences
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2007-12)
This paper presents an overview of the recommendations for achieving 15% above-code energy performance for single-family residences. The analysis was performed using a simulation model of an International Energy Conservation ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Vol. II - Technical Report
(2006-11-01)
The Energy Systems Laboratory, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. § 388.003 (e), Vernon Supp. 2002, submits its fourth annual report, Energy Efficiency/Renewable Energy (EE/RE) ...
Statewide Air Emissions Calculations from Wind and Other Renewables, Summary Report: A Report to the Texas Commission on Environmental Quality for the Period September 2007 - August 2008
(Energy Systems Laboratory, 2008-08)
The 79th Legislature, through Senate Bill 20, House Bill 2481 and House Bill 2129, amended Senate Bill 5 to enhance its effectiveness by adding 5,880 MW of generating capacity from renewable energy technologies by 2015 and ...
Recommendations for 15% Above-Code Energy Efficiency Measures on Implementing Houston Amendments to Single-Family Buildings in Houston Texas
(2008-11)
This report presents detailed information about the analysis that was performed to calculate the energy saving potential for residential buildings in Houston. In this analysis the energy efficient measures were proposed ...