Show simple item record

dc.contributorAsia Turbomachinery & Pump Symposium (3rd : 2022)
dc.creatorKamal, Girish
dc.date.accessioned2023-01-25T22:57:02Z
dc.date.available2023-01-25T22:57:02Z
dc.date.issued2022
dc.identifier.urihttps://hdl.handle.net/1969.1/197012
dc.descriptionCase Studies
dc.description.abstractOff Spec Condensate Recycle Pumps on an onshore gas production facility exhibited high lube oil temperature in pump bearing housing that exceeded the alert limits since commissioning. A Structured Root Cause Analysis was carried out to ascertain the cause of the high lube oil temperature that identified a large variation in pumping medium specific gravity as against the design data. This case study will cover review of the pump design, problem history, structured root cause analysis conducted, solution implemented, along with results and lessons learnt.
dc.format.mediumElectronic
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherTurbomachinery Laboratory, Texas A&M Engineering Experiment Station
dc.relation.ispartofAsia Turbomachinery & Pump Symposium. 2022 Proceedings.
dc.titleCase Study on Investigation and Resolution of High Lube Oil Pump Bearing Temperature for Off Spec. Condensate Recycle Pumps
dc.type.genreconference publication
dc.type.materialText
dc.format.digitalOriginborn digital


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record