Show simple item record

dc.contributor.otherInternational Pump Users Symposium (34th : 2018)
dc.creatorFirst, Rick
dc.creatorGoodwin, Fred
dc.creatorAdams, Christopher
dc.creatorTermunde, Daniel
dc.date.accessioned2019-03-12T19:49:04Z
dc.date.available2019-03-12T19:49:04Z
dc.date.issued2018
dc.identifier.urihttps://hdl.handle.net/1969.1/175034
dc.descriptionTutorialen
dc.description.abstractRecently, there has been a trend in the way new equipment is being mounted that affects precision grouting during installation. Improper grouting not only wastes material, but can result in misalignment, unnecessary vibration, and premature equipment failure. Traditionally, new equipment was mounted on a continuous steel base plate, but skid mounted equipment has a deep central cavity that must be filled to act as an inertia block requiring very deep grout placement. Techniques to utilize both cementitious and deep pour epoxy grouts will be described to provide adequate equipment support and prevent overflow of the shoulders. A focus on high speed turbomachinery will be made to tie reliability to proper installation of precision grout.en
dc.format.mediumElectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherTurbomachinery Laboratory, Texas A&M Engineering Experiment Station
dc.relation.ispartofProceedings of the 34th International Pump Users Symposiumen
dc.subject.lcshPumping machineryen
dc.titlePrecision Grouting of Critical Rotating Equipmenten
dc.type.genreconference publicationen
dc.type.materialTexten
dc.format.digitalOriginborn digitalen