Now showing items 1-10 of 25
Reducing Energy Costs in the Texas State Agencies: Conservation and Policy Options: Volume II – Final Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1984)
Cogeneration System Analysis Summary Reports for Austin State Hospital, Austin, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1985)
Energy Analysis and Energy Conservation Options for the Addition to Records Storage Building
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1986)
The energy use and peak load requirements of the addition to
Records Storage Building in Austin, Texas were analyzed using the
DOE 2.1B building energy simulation program. An analysis was made
for the building as specified ...
An Analysis of Efficiency Improvements in Residential Sized Heat Pumps and Central Air Conditioners
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1986)
This report summarizes: (1) the performance improvements
possible for central air conditioners and heat pumps using
conventional design improvements, (2) the development of a
methodology for estimating the seasonal ...
Energy Analysis and Energy Conservation Option for the Warehouse Facility at the Human Services Center Complex
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1986)
The energy use of the warehouse facility at the Human
Services Center Complex in Austin, Texas was analyzed using the
DOE-2.1B building energy simulation program. An analysis was made
for each building as specified in ...
An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1989)
The effect of the improper charging on steady state and
cyclic performance (capacity, EER, power consumption, SEER,
and coefficient of degradation) of a residential air
conditioner which utilized a thermal expansion ...
Determination of the Transient Response Characteristics of the Air-Source Heat Pump During the Reverse Cycle Defrost
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1988)
The objectives of this research were to: (1)
characterize the reverse cycle defrost of the air-to-air
heat pump and (2) examine the effect of different expansion
devices on the performance of the heat pump during ...
An Evaluation of Steady-State Dehumidification Characteristics of Residential Central Air Conditioners, Final Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1987)
This report is the first of two reports on the project
"Determination of the Transient Response Characteristics of High
Efficiency Commercial Air Conditioners" funded by Houston Lighting and
Power Company. The purpose ...
An Energy and Peak Loads Analysis of the Texas Department of Health Building, Final Report, Prepared for the Energy Efficiency Division, Texas Public Utility Commission
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1986)
Cogeneration System Analysis Summary Reports for Texas Woman’s University, Denton, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1985)