Browsing Technical Reports by Title
Now showing items 11-30 of 407
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)The Energy and Environmental Data System (EEDS) is a web application that facilitates web-based viewing of the Energy Systems Lab's extensive building energy databases. EEDS is the initial framework for a growing set of ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)This manual outlines the procedures to collect data, poll the datalogger, and process the data. The processed data is then used with a calibrated DOE-2 input file using statistical graphing routines for the U.S.D.O.E. ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)This report contains engineering calculations for seven (7) air-side, heating, ventilating and air conditioning systems (HVAC) systems, including: dual duct constant volume (DDCAV), dual duct variable volume (DDVAV), ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)This report contains engineering calculations for four (4) air-side, heating, ventilating and air-conditioning systems (HVAC) systems, including: dual duct constant volume (DDCAV), dual duct variable volume (DDVAV), constant ...
-
(2009-08)The purpose of this report is to provide an analysis of residential energy efficiency and renewable measures that would exceed the 2009 edition of the International Energy Conservation Code (IECC) in the ONCOR service ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1986)The objectives of this study included: (1) development of classes of heat pumps, (2) evaluation and selection of a suitable heat pump design model, (3) characterization of suitable baseline heat pump designs, (4) selection ...
-
An Analysis of Efficiency Improvements in Residential Sized Heat Pumps and Central Air Conditioners (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1986)This report summarizes: (1) the performance improvements possible for central air conditioners and heat pumps using conventional design improvements, (2) the development of a methodology for estimating the seasonal ...
-
(Lawrence Berkeley Laboratory, University of California, 1985)The objectives of this study included: (1) development of classes of heat pumps, (2) evaluation and selection of a suitable heat pump design model, (3) characterization of suitable baseline heat pump designs, (4) selection ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1988)
-
(2008-07-18)In August 2004, the Environmental Protection Agency (EPA) issued guidance on quantifying the air emissions benefits from electric sector energy efficiency and renewable energy. Because there was no clear best strategy, ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-02)In August 2004, the USEPA issued guidance on quantifying the air emission benefits from electric sector energy efficiency and renewable energy. Because there was no clear best strategy, the EPA’s guidance provided a ...
-
(2010-03)In August 2004, the USEPA issued guidance on quantifying the air emission benefits from electric sector energy efficiency and renewable energy. Because there was no clear best strategy, the EPA’s guidance provided a framework ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1993)The Child Development Center (CDC) was designed to be a "showpiece" model building. Its construction included energy efficient features, including a photovoltaic system, solar hot water system, energy efficient lighting, ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)The U.S.D.O.E. Forrestal Child Development Center (CDC) was designed to be a "showpiece" model building. Its construction included energy efficient features such as efficient lighting, a photovoltaic system, an energy ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1997)This report presents an analysis of the HVAC system at the Willow Branch Intermediate School for the MEEN 685 class project. The school is located at College Station, Texas. A portion of the school belonged to Oakwood ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2013)The Energy Systems Laboratory (ESL) of The Texas A&M University System is under contract with Alamo Colleges to conduct energy management, implement the Continuous Commissioning? (CC?)1 process and assist with various ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 2007-04)
-
(Energy Systems Laboratory, 2013-10)
-
(Energy Systems Laboratory, 2008-06)This report describes the application and verification of duct model on DOE 2.1e version 119 using ASHRAE 152-2004 (Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution ...