Search
Now showing items 131-140 of 236
Whole-Campus Performance Analysis Methods: Early Results from Studies at the Princeton Campus
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1989)
The Princeton University Campus provides an
excellent opportunity for evaluating energy data
analysis techniques that use historical energy
consumption data for the entire campus to target
conservation opportunities. The ...
The Texas LoanSTAR Program: Acquiring and Archiving LoanSTAR Data
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
This paper discusses the acquisition and archiving of data for the
Texas LoanSTAR monitoring program, an eight year, $98
million revolving loan program for energy conservation retrofits
in Texas state, local government and ...
Development of a Web-based Emissions Reduction Calculator for Solar Thermal and Solar Photovoltaic Installations
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2005)
Baseline Report for the Fort Hood Army Base: Sept. 1, 2001 To Aug. 31, 2002
(2002-12)
This report presents electricity, natural gas and cooling baselines for the thermal plant,
buildings located in the 87000 block, and the III Corp building at Ft. Hood. A baseline
analysis is also presented for the natural ...
Comparison Between TRNSYS Software Simulation and F-Chart Program on Solar Domestic Hot Water System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2012)
This study presents the accuracy test of a TRNSYS Solar Domestic Hot Water (SDHW) System simulation. The testing is based on comparing the results with the F-Chart software. The selected system to carry out the tests was ...
Recommendations for 15% Above ASHRAE 90.1-2007 Code-Compliant Building Energy Efficiency Measures for Small Retail Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2012)
In the 79th Legislature (2005) the Energy Systems Laboratory was required to develop three alternative methods for achieving 15% above-code energy savings in new residential, commercial and industrial construction. The ...
Comparison Between TRNSYS Software Simulation and F-Chart Program on Pool Heating System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2012)
The purpose of this report is to test the accuracy of TRNSYS simulation of Solar Pool Heating System by comparing with F-Chart program which is an authoritative tool to analyze solar system and was developed in 1970s.
This ...
A Simplified Residential Base-Case Model
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2013)
This study was for the DOE-2.1e program to develop a simplified residential ASHP house model in Houston, Texas. The house characteristics were based on the standard reference design and requirements as defined in Chapter ...
The USDOE Forrestal Lighting Retrofit: Analysis of Electricity and Thermal Savings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1995)
This report provides an overview of the lighting retrofit and the resultant electricity and thermal savings. It presents results from the whole-building monitoring effort that show that the measured gross electricity savings ...
Use of Energy Management and Control Systems for Performance Monitoring of Retrofit Projects: Final Summary Report for USDOE Office of Conservation and Energy, Final Revision, March 1993
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
Traditionally, Energy Management and Control Systems (EMCSs) have been used to control
HVAC, lighting, fire and security systems in buildings. Few EMCSs are used for long term
trending and analysis of energy use (i.e., ...