Search
Now showing items 21-30 of 48
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP) Volume I-Summary Report, Annual Report to the Texas Commission on Environmental Quality, January 2009-December 2009
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-12)
The Energy Systems Laboratory, at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon Supp. 2002, ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP) Volume III- Technical Appendix, Annual Report to the Texas Commission on Environmental Quality, January 2009 – December 2009
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-12)
The Energy Systems Laboratory, at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon Supp. 2002, ...
A Methodology for Calculating Emissions Reductions from Renewable Energy Programs and its Application to the Wind Farms in the Texas ERCOT Region
(Energy Systems Laboratory (http://esl.tamu.edu), 2007-12)
TCEQ Annual 2010 Preliminary Report
(Energy Systems Laboratory, Texas A&M University, 2011-10)
Going Beyond a Resnet Certification for Code-Compliant Simulations: A Sensitivity Analysis of Detailed Results of Three RESNET-Certified, Code-Compliant Residential Simulation Programs
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
In many states building code officials rely on certified, code-compliant simulations to determine whether or not a residence satisfies the energy code requirements using a performance-path analysis. In the United States, ...
Recommendations for 15% Above-Code Energy Efficiency Measures on Implementing Houston Amendments to Multifamily Residential Buildings in Houston Texas
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)
This paper presents results from an analysis of the energy saving potential for multifamily residential buildings in Houston. In this analysis, the energy efficient measures were proposed by the building officials with the ...
Description and Comparison of the Results of the Proposed House: Habitat for Humanity at Frazier Court, Dallas, Texas, with the 2004 IECC Standard Reference House
(Energy Systems Laboratiry, 2010-09)
The Energy Systems Laboratory was requested to calculate the emissions reductions associated
with the Habitat for Humanity Housing Project at Frazier Court, Dallas Texas. This report presents the
results of the required ...
Development of a Residential Code-compliant Web-based Energy Efficiency Calculator for Texas
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-12)
Since 2001, Texas has been proactive in initiating clean air and energy efficiency-in buildings policies. The Texas Emissions Reduction Plan legislation of 2001 mandated statewide adoption of energy codes; created a 5% ...
A Methodology for Calculating Emissions Reductions from Renewable Energy Programs and Its Application to the Wind Farms in the Texas ERCOT Region
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007-12)
Recently Texas Legislature required adding 5,880 MW of generating capacity from renewable energy technologies by 2015, and 500 MW from non-wind renewables. This legislation also required the Public Utility Commission (PUC) ...
Statewide Air Emissions Calculations From Wind and Other Renewables: Summary Report
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2011)