Case Study of Continuous Commissioning in an Office Building
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
The case study building is a two-story office facility with total floor area of 31000 square feet, of which most is open space office. The HVAC system operates 24 hours a day, 7 days a week. An energy audit was conducted ...
Integrated Commissioning for a Large Medical Facility
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The energy costs of heating, ventilating and
air conditioning usually represents a large
portion of the utility bills for a medical facility.
One large, modem medical center located in the
hot and humid region of southern ...
Optimize the Supply Air Temperature Reset Schedule for a Single-Duct VAV System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The supply air temperature for a single-duct
variable air volume (VAV) system is usually set as a
constant. To minimize the simultaneous cooling and
heating, this supply temperature is often reset based
on either return ...
Variable Speed Drive Volumetric Tracking (VSDVT) for Airflow Control in Variable Air Volume (VAV) Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
An airflow control method has been developed
for variable air volume (VAV) systems. This airflow
control method is named VSD volumetric tracking
(VSDVT) since both the supply and return airflows
are determined using signals ...
A Smart Logic for Conference Room Terminal Box of Single Duct VAV System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
In a modern office building, most occupied rooms are relatively isolated from the outdoor air climate conditions. To ensure acceptable indoor air quality (IAQ), ASHRAE 62 explains how to design and construct a space that ...
Integrated Demand Controlled Ventilation for Single Duct VAV System with Conference Rooms
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
Single duct variable air volume (VAV) systems are widely used in office buildings to achieve energy savings. It supplies proper amount of conditioned air to satisfy both the load and the ventilation requirements of each ...
VAV System Optimization through Continuous Commissioning in an Office Building
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
This paper demonstrates the implementation of new innovative technologies during continuous commissioning (CC®) practices to improve building operations and reduce energy costs. The case study building is a 5-story office ...
Supply Fan Control for Constant Air Volume Air Handling Units
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
Since terminal boxes do not have a modulation damper in constant volume (CV) air handling unit (AHU) systems, zone reheat coils have to be modulated to maintain the space temperature with constant supply airflow. This ...
Laboratory Air Handling Unit System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
An innovative AHU system is presented in this paper.
The proposed AHU system is called a Laboratory Air
Handling Unit (LAHU) system since it is most
suitable for the buildings where one section
(laboratory) has 100% exhaust ...
Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
The supply air temperature set point for a singleduct
constant air volume air handling unit (AHU)
system is often reset based on either return air
temperature or outside air temperature in order to
reduce simultaneous ...