dc.contributor.other | International Pump Users Symposium (23rd : 2007) | |
dc.creator | Monroe, Todd | |
dc.creator | Monroe, Perry | |
dc.date.accessioned | 2017-10-05T15:22:22Z | |
dc.date.available | 2017-10-05T15:22:22Z | |
dc.date.issued | 2007 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/163941 | |
dc.description | Tutorial | en |
dc.description | pg. 99 | en |
dc.description.abstract | The purpose of this paper is to take a “back to basics” look at installation issues that affect pump reliability. Topics of hydraulic fit, baseplate installation, shaft alignment, and piping alignment will be discussed. | en |
dc.format.medium | Electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | |
dc.publisher | Texas A&M University. Turbomachinery Laboratories | |
dc.relation.ispartof | Proceedings of the 23rd International Pump Users Symposium | en |
dc.subject.lcsh | Pumping machinery | en |
dc.title | Road To Reliable Pumps | en |
dc.type.genre | Presentation | en |
dc.type.material | Text | en |
dc.identifier.doi | https://doi.org/10.21423/R1CD63 | |