dc.contributor.other | Turbomachinery Symposium (4th : 1975) | |
dc.creator | Von Nimitz, Walter W. | |
dc.date.accessioned | 2017-10-05T14:57:46Z | |
dc.date.available | 2017-10-05T14:57:46Z | |
dc.date.issued | 1975 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/163828 | |
dc.description | Paper | en |
dc.description | Pg. 47-54. | en |
dc.description.abstract | Low frequency vibrations at centrifugal compressor and pump installations are usually discarded as unlikely. However, severe acoustically excited vibrations at frequencies as low as 5 or 10 Hz have been observed at a number of plants. The paper discusses some of the excitation mechanisms and techniques available for their control. Several field study examples illustrate typical problems and their solutions. | en |
dc.format.medium | Electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | |
dc.publisher | Texas A&M University. Gas Turbine Laboratories | |
dc.relation.ispartof | Proceedings of the 4th Turbomachinery Symposium | en |
dc.subject.lcsh | Turbomachines | en |
dc.title | Low Frequency Vibrations At Centrifugal Plants | en |
dc.type.genre | Presentation | en |
dc.type.material | Text | en |
dc.identifier.doi | https://doi.org/10.21423/R1ZT1M | |