Now showing items 1-2 of 2

    • Souers, Bobby (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station; Texas A & M University. Libraries, 2022)
      Metallurgy upgrades for high TAN crudes and existing NPSH problems required the installation of two (2) new Atmospheric Towers and two (2) new Vacuum Tower Bottoms Pumps. • The new pumps are 450 HP and 1800 rpm versus ...
    • Souers, Bobby (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station; Texas A & M University. Libraries, 2022)
      An ubiquitous multistage boiler feed water pump for a SMR Hydrogen Plant in a refinery was specified to meet feed water requirements at plant design hydrogen capacity and at a turndown rate. During testing, it was discovered ...