Browsing by Author "Liu, C."
Now showing items 1-10 of 10
-
Turner, W. D.; Bruner, H., Jr.; Claridge, D.; Liu, C.; Deng, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)More and more variable frequency devices (VFD) are being installed on the chilled water and hot water pumps on the TAMU campus. Those pump speeds are varied to maintain chilled water or hot water building deferential ...
-
Wang, H.; Wang, Z.; Liu, C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)The effects of different states of air supply and airflow patterns on temperature gradient distribution are calculated and analyzed with the help of FFSV3.0 software, using the LB models and LES and RANS methods. An ...
-
Liu, C.; Bruner, H. L.; Deng, S.; Brundidge, T.; Turner, W. D.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)McKenzie Airport Terminal is located at Easterwood Airport, which is owned and operated by Texas A&M University. It was built in 1988. Most all HVAC equipment, which includes boiler, chiller, pumps, AHUs and exhaust fans, ...
-
Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)A multi-functional institutional building often has ventilation and comfort requirements that vary widely from zone to zone. When we commissioned the Reed McDonald building on the main campus of Texas A&M University (TAMU), ...
-
Liu, C.; Zeig, M.; Claridge, D. E.; Wei, G.; Bruner, H.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2005)
-
Han, Z.; Liu, C.; Sun, J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)Existing building energy retrofit is one of the keys of building energy efficiency in China. According to experience in developed countries, implementation of energy management contract (EMC) is crucial to promote existing ...
-
Liu, C.; Turner, W. D.; Claridge, D. E.; Deng, S.; Bruner, H. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)An investigation into the increase of energy consumption of G. Rollie White Coliseum was part of the persistence project[1], which investigates the savings in energy consumption of ten buildings that were commissioned by ...
-
Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2003)The Langford “A” building houses the College of Architecture on TAMU campus. There are ten singleduct variable air volume (VAV) air-handling units (AHUs) without reheat serving the building. The local pneumatic thermostats ...
-
Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H., Jr. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)Cushing Library located on TAMU campus is a special building, which needs precise temperature and relative humidity control, because it stores a number of rare collections and memorial books. There are five air-handling ...
-
Liu, C.; Yang, P.; Minnis, P.; Loeb, N.; Kato, S.; Heymsfield, A.; Schmitt, C. (Atmospheric Chemistry and Physics, 2014)