Claridge, D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)
-
Chen, H.; Deng, S.; Hugghins, J.; Brundidge, T.; Claridge, D.; Turner, W. D.; Bruner, H., Jr. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)Continuous Commissioning (CCSM) was performed on the Texas A&M Large Animal Hospital in October 1996 and as a result, significant savings were achieved. Subsequently, the building chilled water and hot water energy consumption ...
-
Wei, G.; Turner, W. D.; Claridge, D.; Liu, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)The supply air temperature set point for a singleduct constant air volume air handling unit (AHU) system is often reset based on either return air temperature or outside air temperature in order to reduce simultaneous ...
-
Haberl, J.; Liu, Z.; Baltazar-Cervantes, J. C.; Gilman, D.; Culp, C.; Yazdani, B.; Claridge, D.; Mao, C.; Sun, Y.; Narayanaswamy, A.; Do, S.; Kim, K (Energy Systems Laboratory (http://esl.tamu.edu), 2010-12)
-
Haberl, J.S.; Baltazar, J.C.; Yazdani, B.; Claridge, D.; Do, S.L.; Oh, S. (Energy Systems Lab, 2014-07)
-
Haberl, J.; Liu, Z.; Baltazar, J.C.; Gilman, D.; Culp, C.; Yazdani, B.; Claridge, D.; Mao, C.; Sun, Y.; Narayanaswamy, A.; Do, S.; Kim, K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2011)
-
Haberl, J. S.; Baltazar, J. C.; Mao, C.; Culp, C.; Yazdani, B.; Claridge, D.; Do, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)
-
Reddy, T. A.; Claridge, D.; Wu, J. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)Statistical models of energy use in commercial buildings are being increasingly used not only for predicting retrofit savings but also for identifying improper operation of HVAC systems. The conventional approach involves ...
-
Ji, J.; Baltazar, J. C.; Claridge, D. (Energy Systems Laboratory (http://esl.tamu.edu), 2008-12)The energy consumption in a building is affected by many parameters including the occupancy, equipment, schedule time, HVAC systems and outside environment conditions. Currently, the outside air dry-bulb temperature (TOA) ...
-
Lander, B.; Wei, G.; Claridge, D.; Caeiro, J. (Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)The Energy Systems Laboratory at Texas A&M University is currently studying ways to make improvements in thermal comfort at the Terminal E building at DFW airport. Airport terminal building HVAC systems are generally known ...
-
Texas LoanSTAR Monitoring & Analysis Program- Characterizing Loanstar Buildings & Energy Consumption Challa, V.; Athar, A.; Abbas, M.; Claridge, D.; Haberl, J. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)This paper presents an overview of the buildings participating in the Texas LoanSTAR program. In this paper, we categorized the buildings in terms of their number, size, percent area effected, types of buildings, types of ...
-
Challa, V.; Abbas, M.; Athar, A.; Claridge, D.; Haberl, J. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)This paper describes how continuous monitoring and follow-up has improved the savings from energy conservation retrofits in the LoanSTAR program. It describes the importance of the feedback from the facility engineer or ...