Visit the Energy Systems Laboratory Homepage.
Airborne Particulate Matter in HVAC Systems and its Influence on Indoor Air Quality
dc.creator | Fu, Z. | |
dc.creator | Li, N. | |
dc.creator | Wang, H. | |
dc.date.accessioned | 2007-05-07T20:43:53Z | |
dc.date.available | 2007-05-07T20:43:53Z | |
dc.date.issued | 2006 | |
dc.description.abstract | This paper first reviews the mechanisms governing movement of PMs in HVAC systems. Then, the basic equations governing PM deposition in ducts are introduced and investigations on airborne PMs distribution in HVAC systems are reviewed. The influence of PMs on indoor air quality and effectiveness of corresponding controlling measures is discussed extensively in the paper. Finally, recommendations for further research are given. | en |
dc.format.extent | 150892 bytes | en |
dc.format.mimetype | application/pdf | |
dc.identifier.other | ESL-IC-06-11-12 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/5270 | |
dc.language.iso | en_US | |
dc.publisher | Energy Systems Laboratory (http://esl.tamu.edu) | |
dc.publisher | Texas A&M University (http://www.tamu.edu) | |
dc.subject | particulate matter | en |
dc.subject | HVAC system | en |
dc.subject | indoor air quality | en |
dc.subject | IAQ | en |
dc.title | Airborne Particulate Matter in HVAC Systems and its Influence on Indoor Air Quality | en |