Compressor Dry Gas Seal Failure Due To Oil Ingress

Loading...
Thumbnail Image

Date

2018

Journal Title

Journal ISSN

Volume Title

Publisher

Turbomachinery Laboratory, Texas A&M Engineering Experiment Station

Abstract

This case study of a typical tandem arrangement dry gas seal failure during compressor start-up elaborates importance of start-up environment consideration during design for a compressor dry gas seal system. The seal failed due to oil ingress during compressor start-up. The case study presentation details out following major contents: * Chronological events leading to dry gas seal failure, relevant data * Findings/observations during subsequent maintenance * Root cause analysis and outcomes * Corrective actions & subsequent performance * Key learning